Automatic Myotendinous Junction Tracking in Ultrasound Images with Phase-Based Segmentation.

Zhou, Guang-Quan (författare)
Zhang, Yi (författare)
Wang, Ruo-Li (författare)
visa fler...
Zhou, Ping (författare)
Zheng, Yong-Ping (författare)
Tarassova, Olga (författare)
Arndt, Anton 1968- (författare)
Chen, Qiang (författare)
visa färre...
 (utgivare)
Hindawi Limited 2018
2018
Engelska.
Ingår i: BioMed Research International. - 2314-6133.
  • swepub:Mat__t
Abstract Ämnesord
Stäng  
  • Displacement of the myotendinous junction (MTJ) obtained by ultrasound imaging is crucial to quantify the interactive length changes of muscles and tendons for understanding the mechanics and pathological conditions of the muscle-tendon unit during motion. However, the lack of a reliable automatic measurement method restricts its application in human motion analysis. This paper presents an automated measurement of MTJ displacement using prior knowledge on tendinous tissues and MTJ, precluding the influence of nontendinous components on the estimation of MTJ displacement. It is based on the perception of tendinous features from musculoskeletal ultrasound images using Radon transform and thresholding methods, with information about the symmetric measures obtained from phase congruency. The displacement of MTJ is achieved by tracking manually marked points on tendinous tissues with the Lucas-Kanade optical flow algorithm applied over the segmented MTJ region. The performance of this method was evaluated on ultrasound images of the gastrocnemius obtained from 10 healthy subjects (26.0±2.9 years of age). Waveform similarity between the manual and automatic measurements was assessed by calculating the overall similarity with the coefficient of multiple correlation (CMC).<italic> In vivo</italic> experiments demonstrated that MTJ tracking with the proposed method (CMC = 0.97±0.02) was more consistent with the manual measurements than existing optical flow tracking methods (CMC = 0.79±0.11). This study demonstrated that the proposed method was robust to the interference of nontendinous components, resulting in a more reliable measurement of MTJ displacement, which may facilitate further research and applications related to the architectural change of muscles and tendons. [ABSTRACT FROM AUTHOR]

Ämnesord

Engineering and Technology  (hsv)
Medical Engineering  (hsv)
Medical Laboratory and Measurements Technologies  (hsv)
Teknik och teknologier  (hsv)
Medicinteknik  (hsv)
Medicinsk laboratorie- och mätteknik  (hsv)
Medicin/Teknik  (gih)
Medicine/Technology  (gih)

Nyckelord

Surgetendon Ry
Calf Muscles
Surgery
Algorithms
Automation
Correlation (Statistics)
Dislocations (Anatomy)
Tendons
Ultrasonic Imaging
Wave Analysis
Computer-Assisted Surgery
In Vivo Studies