SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Li Yi Ping)
 

Sökning: WFRF:(Li Yi Ping) > Automatic Myotendin...

  • Zhou, Guang-Quan (författare)

Automatic Myotendinous Junction Tracking in Ultrasound Images with Phase-Based Segmentation.

  • E-artikel/E-kapitelEngelska2018

Förlag, utgivningsår, omfång ...

  • Hindawi Limited2018

Nummerbeteckningar

  • LIBRIS-ID:22528972
  • http://urn.kb.se/resolve?urn=urn:nbn:se:gih:diva-5234uri
  • urn:nbn:se:gih:diva-5234urn
  • 10.1155/2018/3697835doi

Kompletterande språkuppgifter

  • Språk:engelska

Ingår i deldatabas

Anmärkningar

  • Published
  • gratis
  • Displacement of the myotendinous junction (MTJ) obtained by ultrasound imaging is crucial to quantify the interactive length changes of muscles and tendons for understanding the mechanics and pathological conditions of the muscle-tendon unit during motion. However, the lack of a reliable automatic measurement method restricts its application in human motion analysis. This paper presents an automated measurement of MTJ displacement using prior knowledge on tendinous tissues and MTJ, precluding the influence of nontendinous components on the estimation of MTJ displacement. It is based on the perception of tendinous features from musculoskeletal ultrasound images using Radon transform and thresholding methods, with information about the symmetric measures obtained from phase congruency. The displacement of MTJ is achieved by tracking manually marked points on tendinous tissues with the Lucas-Kanade optical flow algorithm applied over the segmented MTJ region. The performance of this method was evaluated on ultrasound images of the gastrocnemius obtained from 10 healthy subjects (26.0±2.9 years of age). Waveform similarity between the manual and automatic measurements was assessed by calculating the overall similarity with the coefficient of multiple correlation (CMC).<italic> In vivo</italic> experiments demonstrated that MTJ tracking with the proposed method (CMC = 0.97±0.02) was more consistent with the manual measurements than existing optical flow tracking methods (CMC = 0.79±0.11). This study demonstrated that the proposed method was robust to the interference of nontendinous components, resulting in a more reliable measurement of MTJ displacement, which may facilitate further research and applications related to the architectural change of muscles and tendons. [ABSTRACT FROM AUTHOR]

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Zhang, Yi (författare)
  • Wang, Ruo-Li (författare)
  • Zhou, Ping (författare)
  • Zheng, Yong-Ping (författare)
  • Tarassova, Olga (författare)
  • Arndt, Anton1968- (författare)
  • Chen, Qiang (författare)
  • Gymnastik- och idrottshögskolan, GIHInstitutionen för idrotts- och hälsovetenskap (utgivare)

Sammanhörande titlar

  • Del av/supplement till:channel record
  • Ingår i:VärdpublikationBioMed Research International2314-6133

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy