SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Collins Rory)
 

Sökning: WFRF:(Collins Rory) > (2016) > Feasibility of MR-b...

Feasibility of MR-based Body Composition Analysis in Large Scale Population Studies

West, Janne (författare)
Dahlqvist Leinhard, Olof (författare)
Romu, Thobias, 1984- (författare)
visa fler...
Collins, Rory (författare)
Garratt, Steve (författare)
Bell, Jimmy (författare)
Borga, Magnus (författare)
Thomas, E. Louise (författare)
visa färre...
 (utgivare)
 (utgivare)
visa fler...
 (utgivare)
 (utgivare)
 (utgivare)
 (utgivare)
 (utgivare)
visa färre...
Public Library of Science 2016
2016
Engelska.
Ingår i: PLoS ONE. - 1932-6203. ; 11:9
  • swepub:Mat__t
Abstract Ämnesord
Stäng  
  • Introduction Quantitative and accurate measurements of fat and muscle in the body are important for prevention and diagnosis of diseases related to obesity and muscle degeneration. Manually segmenting muscle and fat compartments in MR body-images is laborious and time-consuming, hindering implementation in large cohorts. In the present study, the feasibility and success-rate of a Dixon-based MR scan followed by an intensity-normalised, non-rigid, multi-atlas based segmentation was investigated in a cohort of 3,000 subjects. Materials and Methods 3,000 participants in the in-depth phenotyping arm of the UK Biobank imaging study underwent a comprehensive MR examination. All subjects were scanned using a 1.5 T MR-scanner with the dual-echo Dixon Vibe protocol, covering neck to knees. Subjects were scanned with six slabs in supine position, without localizer. Automated body composition analysis was performed using the AMRA Profiler™ system, to segment and quantify visceral adipose tissue (VAT), abdominal subcutaneous adipose tissue (ASAT) and thigh muscles. Technical quality assurance was performed and a standard set of acceptance/rejection criteria was established. Descriptive statistics were calculated for all volume measurements and quality assurance metrics. Results Of the 3,000 subjects, 2,995 (99.83 %) were analysable for fat, 2,828 (94.27 %) were analysable when fat and one thigh was included, and 2,775 (92.50 %) were fully analysable for fat and both thigh muscles. Reasons for not being able to analyse datasets were mainly due to missing slabs in the acquisition, or patient positioned so that large parts of the volume was outside of the field-of-view. Discussion and Conclusions In conclusion, this study showed that the rapid UK Biobank MR-protocol was well tolerated by most subjects and sufficiently robust to achieve very high success-rate for body composition analysis. This research has been conducted using the UK Biobank Resource.

Ämnesord

Medical and Health Sciences  (hsv)
Clinical Medicine  (hsv)
Radiology, Nuclear Medicine and Medical Imaging  (hsv)
Medicin och hälsovetenskap  (hsv)
Klinisk medicin  (hsv)
Radiologi och bildbehandling  (hsv)
Engineering and Technology  (hsv)
Medical Engineering  (hsv)
Medical Image Processing  (hsv)
Teknik och teknologier  (hsv)
Medicinteknik  (hsv)
Medicinsk bildbehandling  (hsv)

Nyckelord

Magnetic Resonance
Body Composition Analysis
Population Study
Dixon protocol
Quality Control
Quantitative MRI

Hitta via bibliotek

  • PLoS ONE (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy