SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Dhar A.)
 

Sökning: WFRF:(Dhar A.) > Performance evaluat...

Performance evaluation of a parabolic trough collector with a uniform helical wire coil flow insert

Saini, P. (författare)
Dhar, A. (författare)
Powar, Satvasheel (författare)
Högskolan Dalarna,Energiteknik,Indian Institute of Technology Mandi, India
 (creator_code:org_t)
Elsevier, 2024
2024
Engelska.
Ingår i: Results in Engineering (RINENG). - : Elsevier. - 2590-1230. ; 21
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Solar energy is an extremely useful and dependable renewable energy source for meeting our society's diverse energy demands. Solar concentrator-based energy systems are currently the most efficient methods of using solar energy. Among these technologies, the parabolic trough collector is a mature and effective concentrating solar power technology with a wide range of real-world applications using solar alone or in combination with other energy sources. Flow insert is a potential approach for improving parabolic trough solar collector performance through enhanced heat transfer and heat absorption. The purpose of this study is to determine the feasibility of using a uniform helical wire coil flow insert in the LS-2 parabolic trough solar collector module. A computational fluid dynamic model developed in Ansys 18.1 is used in the current investigation. A uniform helical wire coil flow insert is modeled and compared with the plain tube without any insert inside it. Flow analysis, overall efficiency, exergy efficiency, and thermal efficiency are compared in the evaluation process. The overall efficiency and exergy efficiency of the parabolic trough collector are the most critical criteria in determining its performance. The parabolic trough collector is examined using a range of inlet fluid temperatures ranging from 303 K to 603 K and a volumetric flow rate of 50 L per minute to 250 L per minute. The pumping work is found to be the lowest, indicating that the increase in pressure drop has a negligible effect on the overall system performance. For the flow rate of 50 L per minute and inlet heat transfer fluid temperature of 303 K, the overall, exergy and thermal efficiency using a uniform helical wire coil flow insert are found to be 2.07 %, 2.1 %, and 2.2 %, respectively. © 2024 The Authors

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Energiteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Energy Engineering (hsv//eng)

Nyckelord

Exergy efficiency
Overall efficiency
Parabolic trough collector (PTC)
Uniform helical wire coil flow insert
Collector efficiency
Computational fluid dynamics
Concentrated solar power
Exergy
Heat transfer
Thermal efficiency
Wire
Exergy efficiencies
Helical wires
Parabolic trough collector
Parabolic trough collectors
Parabolic trough solar collectors
Performance
Thermal-efficiency
Wire-coils
Solar energy

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Saini, P.
Dhar, A.
Powar, Satvashee ...
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Maskinteknik
och Energiteknik
Artiklar i publikationen
Results in Engin ...
Av lärosätet
Högskolan Dalarna

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy