Validity of the Oxycon Mobile metabolic system under field measuring conditions

Salier Eriksson, Jane (författare)
Gymnastik- och idrottshögskolan,FoU-gruppen för rörelse, hälsa och miljö,Swedish Sch Sport & Hlth, Lab Appl Sport Sci, GIH, Stockholm, Sweden
Rosdahl, Hans (författare)
Gymnastik- och idrottshögskolan,FoU-gruppen för rörelse, hälsa och miljö,Swedish Sch Sport & Hlth, Lab Appl Sport Sci, GIH, Stockholm, Sweden
Schantz, Peter (författare)
Mittuniversitetet,Gymnastik- och idrottshögskolan,FoU-gruppen för rörelse, hälsa och miljö,Institutionen för hälsovetenskap (-2013)
 (creator_code:org_t)
2011-05-11
2012
Engelska.
Ingår i: European Journal of Applied Physiology. - : Springer. - 1439-6319 .- 1439-6327. ; 112:1, s. 345-355
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Abstract Purpose: It is essential to validate portable metabolic systems, not only in laboratory settings, but also in field measuring conditions, such as prolonged moderate exercise at low temperatures, high humidity and with external wind. Methods: VO2, VCO2, RER and VE were measured using the Oxycon Mobile (OM), with a windshield, during cycle ergometer exercise: (I) indoors at three submaximal workloads with no wind or with external wind (13–20 m·s-1) from front, side and back; (II) at two submaximal workloads outdoors (12 ± 2oC; 86 ± 7% RH), with and without a system for drying the ambient air around the air sampling tube; and (III) at one workload outdoors for 45 min (5 ± 4oC; 69 ± 16.5% RH). Any physiological drift was checked for with pre- and postmeasurements by the Douglas bag method (DBM). Results: A minor effect of external wind from behind was noted in RER and VE (-2 and -3%).. The system for drying the ambient air around the gas sampling tube had no effect on the measured levels. A small difference in VCO2 drift between the OM and DBM (1.5 mL·min-2) was noted in the stability test. Conclusion: Heavy external wind applied from different directions generally does not affect the measurements of the OM. Furthermore, when using a unit for drying the ambient air around the gas sampling tube, the OM can accurately measure VO2, RER and VE   at submaximal workloads for at least45 min under challenging conditions with regard to humidity and temperature.  

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap -- Idrottsvetenskap (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences -- Sport and Fitness Sciences (hsv//eng)

Nyckelord

Oxycon Mobile
Douglas bag method
external wind
humidity
temperature
stability
Sports
Idrott
Medicin/Teknik
Medicine/Technology

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy