  • Ekblom, Örjan,1971-Gymnastik- och idrottshögskolan,Björn Ekbloms forskningsgrupp (författare)

Validity and comparability of a wrist-worn accelerometer in children.

  • Artikel/kapitelEngelska2012

Förlag, utgivningsår, omfång ...

  • Human Kinetics,2012
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:gih-2237
  • https://urn.kb.se/resolve?urn=urn:nbn:se:gih:diva-2237URI
  • http://kipublications.ki.se/Default.aspx?queryparsed=id:124304111URI
  • https://doi.org/10.1123/jpah.9.3.389DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • BACKGROUND:Wrist-worn accelerometers may provide an alternative to hip-worn monitors for assessing physical activity as they are easier to wear and may thus facilitate long-term recordings. The current study aimed at a) assessing the validity of the Actiwatch (wrist-worn) for estimating energy expenditure, b) determining cut-off values for light, moderate, and vigorous activities, c) studying the comparability between the Actiwatch and the Actigraph (hip-worn), and d) assessing reliability.METHODS:For validity, indirect calorimetry was used as criterion measure. ROC-analyses were applied to identify cut-off values. Comparability was tested by simultaneously wearing of the 2 accelerometers during free-living condition. Reliability was tested in a mechanical shaker.RESULTS:All-over correlation between accelerometer output and energy expenditure were found to be 0.80 (P < .001).Based on ROC-analysis, cut-off values for 1.5, 3, and 6 METs were found to be 80, 262, and 406 counts per 15 s, respectively. Energy expenditure estimates differed between the Actiwatch and the Actigraph (P < .05). The intra- and interinstrument coefficient of variation of the Actiwatch ranged between 0.72% and 8.4%.CONCLUSION:The wrist-worn Actiwatch appears to be valid and reliable for estimating energy expenditure and physical activity intensity in children aged 8 to 10 years.

Ämnesord och genrebeteckningar

  • Medicin/Teknik
  • Medicine/Technology

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Nyberg, GiselaKarolinska Institutet(Swepub:gih)gisela.nyberg (författare)
  • Ekblom Bak, ElinGymnastik- och idrottshögskolan,Björn Ekbloms forskningsgrupp(Swepub:gih)eline (författare)
  • Ekelund, UlfCambridge University,MRC Epidemiology (författare)
  • Marcus, ClaudeKarolinska Institutet (författare)
  • Gymnastik- och idrottshögskolanBjörn Ekbloms forskningsgrupp (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Journal of Physical Activity and Health: Human Kinetics9:3, s. 389-3931543-30801543-5474