SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Ørtenblad Niels)
 

Sökning: WFRF:(Ørtenblad Niels) > Reliability of maxi...

Reliability of maximal mitochondrial oxidative phosphorylation in permeabilized fibers from the vastus lateralis employing high-resolution respirometry.

Cardinale, Daniele A (författare)
Gymnastik- och idrottshögskolan,Forskningsgruppen Mitokondriell funktion och metabol kontroll,Elite Performance Centre, Bosön
Gejl, Kasper D (författare)
University of Southern Denmark
Ørtenblad, Niels (författare)
University of Southern Denmark
visa fler...
Ekblom, Bjorn (författare)
Gymnastik- och idrottshögskolan,Björn Ekbloms forskningsgrupp
Blomstrand, Eva (författare)
Gymnastik- och idrottshögskolan,Eva Blomstrands forskningsgrupp
Larsen, Filip J (författare)
Gymnastik- och idrottshögskolan,Forskningsgruppen Mitokondriell funktion och metabol kontroll
visa färre...
 (creator_code:org_t)
2018-02-21
2018
Engelska.
Ingår i: Physiological Reports. - : Wiley. - 2051-817X. ; 6:4
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The purpose was to assess the impact of various factors on methodological errors associated with measurement of maximal oxidative phosphorylation (OXPHOS) in human skeletal muscle determined by high-resolution respirometry in saponin-permeabilized fibers. Biopsies were collected from 25 men to assess differences in OXPHOS between two muscle bundles and to assess the correlation between OXPHOS and the wet weight of the muscle bundle. Biopsies from left and right thighs of another five subjects were collected on two occasions to compare limbs and time-points. A single muscle specimen was used to assess effects of the anesthetic carbocaine and the influence of technician. The difference in OXPHOS between two fiber-bundles from the same biopsy exhibited a standard error of measurement (SEM) of 10.5 pmol · s-1  · mg-1 and a coefficient of variation (CV) of 15.2%. The differences between left and right thighs and between two different time-points had SEMs of 9.4 and 15.2 pmol · s-1  · mg-1 and CVs of 23.9% and 33.1%, respectively. The average (±SD) values obtained by two technicians monitoring different bundles of fibers from the same biopsy were 31.3 ± 7.1 and 26.3 ± 8.1 pmol · s-1  · mg-1 . The time that elapsed after collection of the biopsy (up to a least 5 h in preservation medium), wet weight of the bundle (from 0.5 to 4.5 mg) and presence of an anesthetic did not influence OXPHOS. The major source of variation in OXPHOS measurements is the sample preparation. The thigh involved, time-point of collection, size of fiber bundles, and time that elapsed after biopsy had minor or no effect.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinska och farmaceutiska grundvetenskaper -- Fysiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Basic Medicine -- Physiology (hsv//eng)

Nyckelord

Mitochondria
reliability
standard error of the measurement
Medicin/Teknik
Medicine/Technology

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy