SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Bröms Kristina)
 

Sökning: WFRF:(Bröms Kristina) > One leg testing in ...

One leg testing in hip and knee osteoarthritis : A comparison with a two-leg oriented functional outcome measure and self-reported functional measures.

Bendrik, Regina (författare)
Department of Public Health and Caring Sciences, General Practice, Uppsala University, Uppsala, Sweden; Centre for Research and Development, Uppsala University/Region Gävleborg, Gävle, Sweden
Sundström, Björn, 1968- (författare)
Umeå universitet,Reumatologi,Centre for Research and Development, Uppsala University/Region Gävleborg, Gävle, Sweden
Bröms, Kristina (författare)
Department of Public Health and Caring Sciences, General Practice, Uppsala University, Uppsala, Sweden.
visa fler...
Emtner, Margareta (författare)
Department of Medical Sciences, Uppsala University, Uppsala, Sweden
Kallings, Lena V, Docent, 1969- (författare)
Gymnastik- och idrottshögskolan,Institutionen för fysisk aktivitet och hälsa,Department of Public Health and Caring Sciences, General Practice, Uppsala University, Uppsala, Sweden; Swedish School of Sport and Health Sciences, GIH, Stockholm, Sweden
Peterson, Magnus (författare)
Department of Public Health and Caring Sciences, General Practice, Uppsala University, Uppsala, Sweden; Academic Primary Health Care, Region Uppsala, Sweden
visa färre...
 (creator_code:org_t)
Elsevier, 2024
2024
Engelska.
Ingår i: Osteoarthritis and Cartilage. - : Elsevier. - 1063-4584 .- 1522-9653. ; 32:7, s. 937-942
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • OBJECTIVE: To compare the responsiveness of two unilateral lower-limb performance-based tests, the one-leg rise test and the maximal step-up test, with the bilateral 30-second chair-stand test and the self-reported measure of physical function (HOOS/KOOS). Specific aims were to evaluate responsiveness, floor/ceiling effect and association between the instruments.METHOD: Data was included from 111 participants, mean age 61.3 years (8.3), with clinically verified hip or knee osteoarthritis, who reported less than 150 minutes/week of moderate or vigorous intensity physical activity. Responsiveness, how well the instruments captured improvements, was measured as Cohen's standardised mean difference for effect size, and was assessed from baseline to 12 months following a physical activity intervention. Other assessments were floor and ceiling effects, and correlations between tests.RESULTS: The maximal step-up test had an effect size of 0.57 (95% CI 0.37, 0.77), the 30-second chair-stand 0.48 (95% CI 0.29, 0.68) and the one-leg rise test 0.12 (95% CI 0.60, 0.31). The one-leg rise test had a floor effect as 72% of the participants scored zero at baseline and 63% at 12 months. The correlation between performance-based tests and questionnaires was considered to be minor (r = 0.188 to 0.226) (p = 0.018 to 0.048).CONCLUSION: The unilateral maximal step-up test seems more responsive to change in physical function compared to the bilateral 30-second chair-stand test, although the tests did not differ statistically in effect size. The maximal step-up test provides specific information about each leg for the individual and allows for comparison between the legs.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Reumatologi och inflammation (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Rheumatology and Autoimmunity (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap -- Sjukgymnastik (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences -- Physiotherapy (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap -- Idrottsvetenskap (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences -- Sport and Fitness Sciences (hsv//eng)

Nyckelord

Maximal step-up test
Osteoarthritis
Physical function
Responsiveness
Medicin/Teknik
Medicine/Technology

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy