SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Saul J.)
 

Sökning: WFRF:(Saul J.) > (2020-2023) > Neuromuscular elect...

Neuromuscular electrical stimulation in garments optimized for compliance

Juthberg, R. (författare)
Department of Molecular Medicine and Surgery, Karolinska Institutet, Stockholm, Sweden
Flodin, J. (författare)
Karolinska Institutet
Guo, Li (författare)
Högskolan i Borås,Akademin för textil, teknik och ekonomi,Polymeric E- textiles Group,Smart Textiles and Polymeric E-textiles, Swedish School of Textiles, University of Borås, Borås, Sweden
visa fler...
Rodriguez, Saul (författare)
KTH,Elektronik och inbyggda system,School of Electrical Engineering and Computer Science, KTH Royal Institute of Technology, Stockholm, Sweden
Persson, Nils-Krister (författare)
Högskolan i Borås,Akademin för textil, teknik och ekonomi,Polymeric E- textiles Group,Smart Textiles and Polymeric E-textiles, Swedish School of Textiles, University of Borås, Borås, Sweden
Ackermann, P. W. (författare)
Karolinska Institutet
visa färre...
 (creator_code:org_t)
Springer, 2023
2023
Engelska.
Ingår i: European Journal of Applied Physiology. - : Springer. - 1439-6319 .- 1439-6327.
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • PurposePhysical inactivity is associated with muscle atrophy and venous thromboembolism, which may be prevented by neuromuscular electrical stimulation (NMES). This study aimed to investigate the effect on discomfort, current amplitude and energy consumption when varying the frequency and phase duration of low-intensity NMES (LI-NMES) via a sock with knitting-integrated transverse textile electrodes (TTE).MethodsOn eleven healthy participants (four females), calf-NMES via a TTE sock was applied with increasing intensity (mA) until ankle-plantar flexion at which point outcomes were compared when testing frequencies 1, 3, 10 and 36 Hz and phase durations 75, 150, 200, 300 and 400 µs. Discomfort was assessed with a numerical rating scale (NRS, 0–10) and energy consumption was calculated and expressed in milli-Joule (mJ). Significance set to p ≤ 0.05.Results1 Hz yielded a median (inter-quartile range) NRS of 2.4 (1.0–3.4), significantly lower than both 3 Hz with NRS 2.8 (1.8–4.2), and 10 Hz with NRS 3.4 (1.4–5.4) (both p ≤ .014). Each increase in tested frequency resulted in significantly higher energy consumption, e.g. 0.6 mJ (0.5–0.8) for 1 Hz vs 14.9 mJ (12.3–21.2) for 36 Hz (p = .003). Longer phase durations had no significant effect on discomfort despite generally requiring significantly lower current amplitudes. Phase durations 150, 200 and 400 µs required significantly lower energy consumption compared to 75 µs (all p ≤ .037).ConclusionLI-NMES applied via a TTE sock produces a relevant plantar flexion of the ankle with the best comfort and lowest energy consumption using 1 Hz and phase durations 150, 200 or 400 µs.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Materialteknik -- Textil-, gummi- och polymermaterial (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Materials Engineering -- Textile, Rubber and Polymeric Materials (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Medicinska och farmaceutiska grundvetenskaper -- Fysiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Basic Medicine -- Physiology (hsv//eng)

Nyckelord

Electric stimulation therapy
Pain
Patient comfort
Patient compliance
Textil och mode (generell)
Textiles and Fashion (General)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy