SwePub
Sök i LIBRIS databas

  Utökad sökning

AMNE:(ENGINEERING AND TECHNOLOGY Medical Engineering Medical Laboratory and Measurements Technologies)
 

Sökning: AMNE:(ENGINEERING AND TECHNOLOGY Medical Engineering Medical Laboratory and Measurements Technologies) > Performance of the ...

Performance of the Load-in-the-Loop Single Op-Amp Voltage Controlled Current Source from the Op-Amp Parameters

Macias, Raul (författare)
Biomedical Engineering,Technical University of Catalonia,Department of Electronic Engineering
Seoane, Fernando (författare)
Högskolan i Borås,Institutionen Ingenjörshögskolan,Biomedical Engineering,Chalmers tekniska högskola,Chalmers University of Technology,University of Borås,School of Engineering
Bragos, Ramon (författare)
Biomedical Engineering,Technical University of Catalonia,Department of Electronic Engineering
 (creator_code:org_t)
2010-05-19
2010
Engelska.
Ingår i: Journal of Physics: Conference Series. - : Institute of Physics Publishing Ltd.. - 1742-6596 .- 1742-6588.
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • In recent years, Electrical Bioimpedance (EBI) methods have gained importance. These methods are often based on obtaining impedance spectrum in the range of β-dispersion, i.e. from a few kHz up to some MHz. To measure EBI a constant current is often injected and the voltage across the tissue under study (TUS) is recorded. Due to the performance of the current source influences the performance of the entire system, in terms of frequency range, several designs have been implemented and studied. In this paper the basic structure of a Voltage-Controlled Current Source (VCCS) based on a single Op-Amp in inverter configuration with a floating load, known as load-in-the-loop current source, is revisited and studied deeply. We focus on the dependence of the output impedance with the circuit parameters, i.e. the feedback resistor and the inverter-input resistor, and the Op-Amp main parameters, i.e. open loop gain, CMRR and input impedance. After obtaining the experimental results and comparing to the theoretical and simulated ones, they confirm the design under study can be a good solution for multi-frequency wideband EBI applications because of higher values of the output impedance than 100kΩ at 1MHz are obtained. Furthermore, an enhancement of the basic design, using a current conveyor as a first stage, is proposed, studied and implemented.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Medicinsk bioteknologi -- Biomedicinsk laboratorievetenskap/teknologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Medical Biotechnology -- Biomedical Laboratory Science/Technology (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Annan teknik -- Övrig annan teknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Other Engineering and Technologies -- Other Engineering and Technologies not elsewhere specified (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik -- Reglerteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering -- Control Engineering (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Laboratory and Measurements Technologies (hsv//eng)

Nyckelord

electronic instrumentation
bioimpedance
measurement instrumentation
Medical Electronics

Publikations- och innehållstyp

ref (ämneskategori)
kon (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy