SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:2694 0604
 

Sökning: L773:2694 0604 > Skin-Electrode Cont...

Skin-Electrode Contact Area in Electrical Bioimpedance Spectroscopy. Influence in Total Body Composition Assessment.

Marquez Ruiz, Juan Carlos (författare)
KTH,Högskolan i Borås,Institutionen Ingenjörshögskolan,Medicinska sensorer, signaler och system (MSSS)
Seoane, Fernando (författare)
KTH,Högskolan i Borås,Institutionen Ingenjörshögskolan,Medicinska sensorer, signaler och system (MSSS)
Lindecrantz, Kaj (författare)
Karolinska Institutet,KTH,Högskolan i Borås,Institutionen Ingenjörshögskolan,Medicinska sensorer, signaler och system (MSSS)
 (creator_code:org_t)
ISBN 9781424441211
IEEE, 2011
2011
Engelska.
Ingår i: Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS. - : IEEE. - 9781424441228 ; 2011, s. 1867-70
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • Electrical Bioimpedance Spectroscopy (EBIS) has been widely use for assessment of total body composition and fluid distribution. (EBIS) measurements are commonly performed with electrolytic electrodes placed on the wrist and the ankle with a rather small skin–electrode contact area. The use of textile garments for EBI requires the integration of textrodes with a larger contact area surrounding the limbs in order to compensate the absence of electrolytic medium commonly present in traditional Ag/AgCl gel electrodes. Recently it has been shown that mismatch between the measurements electrodes might cause alterations on the EBIS measurements. When performing EBIS measurements with textrodes certain differences have been observed, especially at high frequencies, respect the same EBIS measurements using Ag/AgCl electrodes. In this work the influence of increasing the skinelectrode area on the estimation of body composition parameters has been study performing experimental EBIS measurement. The results indicate that an increment on the area of the skin-electrode interface did produce noticeable changes in the bioimpedance spectra as well as in the body composition parameters. This influence must be taken into consideration when designing and testing textile-enable EBIS measurement systems.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Industriell bioteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Industrial Biotechnology (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Laboratory and Measurements Technologies (hsv//eng)

Nyckelord

impedance
textile electrodes
EBIS
biomedica engineering
Biomedical Engineering

Publikations- och innehållstyp

ref (ämneskategori)
kon (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy