SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Nowaczyk Sławomir 1978 )
 

Sökning: WFRF:(Nowaczyk Sławomir 1978 ) > Ranking Abnormal Su...

Ranking Abnormal Substations by Power Signature Dispersion

Calikus, Ece, 1990- (författare)
Högskolan i Halmstad,CAISR Centrum för tillämpade intelligenta system (IS-lab)
Nowaczyk, Sławomir, 1978- (författare)
Högskolan i Halmstad,CAISR Centrum för tillämpade intelligenta system (IS-lab)
Pinheiro Sant'Anna, Anita, 1983- (författare)
Högskolan i Halmstad,CAISR Centrum för tillämpade intelligenta system (IS-lab)
visa fler...
Byttner, Stefan, 1975- (författare)
Högskolan i Halmstad,CAISR Centrum för tillämpade intelligenta system (IS-lab)
visa färre...
 (creator_code:org_t)
Amsterdam : Elsevier, 2018
2018
Engelska.
Ingår i: Energy Procedia. - Amsterdam : Elsevier. - 1876-6102. ; 149, s. 345-353
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The relation between heat demand and outdoor temperature (heat power signature) is a typical feature used to diagnose abnormal heat demand. Prior work is mainly based on setting thresholds, either statistically or manually, in order to identify outliers in the power signature. However, setting the correct threshold is a difficult task since heat demand is unique for each building. Too loose thresholds may allow outliers to go unspotted, while too tight thresholds can cause too many false alarms.Moreover, just the number of outliers does not reflect the dispersion level in the power signature. However, high dispersion is often caused by fault or configuration problems and should be considered while modeling abnormal heat demand.In this work, we present a novel method for ranking substations by measuring both dispersion and outliers in the power signature. We use robust regression to estimate a linear regression model. Observations that fall outside of the threshold in this model are considered outliers. Dispersion is measured using coefficient of determination R2 which is a statistical measure of how close the data are to the fitted regression line.Our method first produces two different lists by ranking substations using number of outliers and dispersion separately. Then, we merge the two lists into one using the Borda Count method. Substations appearing on the top of the list should indicate higher abnormality in heat demand compared to the ones on the bottom. We have applied our model on data from substations connected to two district heating networks in the south of Sweden. Three different approaches i.e. outlier-based, dispersion-based and aggregated methods are compared against the rankings based on return temperatures. The results show that our method significantly outperforms the state-of-the-art outlier-based method. © 2018 The Authors. Published by Elsevier Ltd.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)

Nyckelord

abnormal heat demand
district heating
anomaly detection
fault detection
power signature

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy