SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:0960 1481 OR L773:1879 0682
 

Sökning: L773:0960 1481 OR L773:1879 0682 > Thermal modelling a...

Thermal modelling and experimental evaluation of a novel concentrating photovoltaic thermal collector (CPVT) with parabolic concentrator

Afzali Gorouh, Hossein (författare)
Shahid Bahonar University of Kerman, Iran
Salmanzadeh, Mazyar (författare)
Shahid Bahonar University of Kerman, Iran
Nasseriyan, Pouriya (författare)
Shahid Bahonar University of Kerman, Iran
visa fler...
Hayati, Abolfazl (författare)
Högskolan i Gävle,Energisystem och byggnadsteknik
Cabral, Diogo (författare)
Högskolan i Gävle,Energisystem och byggnadsteknik
Gomes, João, 1979- (författare)
Högskolan i Gävle,Energisystem och byggnadsteknik
Karlsson, Björn (författare)
Högskolan i Gävle,Energisystem och byggnadsteknik
visa färre...
 (creator_code:org_t)
Elsevier, 2022
2022
Engelska.
Ingår i: Renewable energy. - : Elsevier. - 0960-1481 .- 1879-0682. ; 181, s. 535-553
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • In the present study, a zero-dimensional thermal model has been developed to analyze a novel low concentration photovoltaic-thermal (CPVT) collector. The model has been developed by driving heat transfer and energy balance equations for each part of the collector and then solving all the equations simultaneously. Moreover, a Monte-Carlo ray-tracing software has been used for optical stimulations of the parabolic trough solar collector. The novel CPVT collector has been experimentally tested at Gävle University (Sweden) and the model has been validated against the experimental results. The primary energy saving equivalent to the thermal-electrical power cogeneration of the CPVT collector has been determined. The effect of glass cover removal, heat transfer fluid (HTF) inlet temperature and mass flow rate on the collector performance has been investigated. The optimum HTF mass flow rates of the collector for maximum electrical yield and overall primary energy saving were determined under specified operating conditions by considering the pump consumption. The effect of mean fluid temperature on the thermal and electrical efficiencies has been studied and the characteristic equation of the thermal efficiency has been obtained. The thermal and electrical peak efficiencies of the collector have been found to be 69.6% and 6.1%, respectively.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Energiteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Energy Engineering (hsv//eng)

Nyckelord

Photovoltaic-thermal collector
Parabolic concentrator
Thermal modelling
Primary energy

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy