Sagittal plane position of the functional joint centre of prosthetic foot-ankle mechanisms

Rusaw, David, 1978- (författare)
Jönköping University,HHJ. Ortopedteknisk plattform,HHJ, Avdelningen för rehabilitering
Ramstrand, Nerrolyn (författare)
Jönköping University,HHJ. Ortopedteknisk plattform,HHJ, Avdelningen för rehabilitering
Jönköping University HHJ Ortopedteknisk plattform (creator_code:org_t)
Elsevier, 2010
2010
Engelska.
Ingår i: Clinical Biomechanics. - : Elsevier. - 0268-0033 .- 1879-1271. ; 25:7, s. 713-720
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: The use of motion analysis techniques in amputee rehabilitation often utilizes kinematic data from the prosthetic limb. A problem with methods currently used is that the joint positions of the prosthetic ankle are assumed to be in the same position as that of an intact ankle. The aim of this study was to identify both traditional anatomical joint centres as well as functional joint centres in a selection of commonly used prosthetic feet. These coordinates were then compared across feet and compared to the contralateral intact ankle joint.Methods: Six prosthetic feet were !t to a unilateral trans-tibial amputee on two separate occasions. The subject's intact limb was used as a control. Three-dimensional kinematics were collected to determine the sagittal position of the functional joint centre for the feet investigated.Findings: None of the prosthetic feet had a functional joint centre that was within the 95% CI for that of an intact ankle (both x- and y-coordinate position), nor any of the other prosthetic feet investigated. The repeatability of the method was found to be adequate, with 95% CI of the difference (test–retest) of the prosthetic feet similar to that for the intact ankle and within clinically accepted levels of variability.Interpretation: The motion of the prosthetic feet tested is clearly different from that of an intact ankle. Kinematic methods that assume ankle constraints based on an intact ankle are subject to systematic error as this does not refect the real motion of the prosthetic foot.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Ortopedi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Orthopaedics (hsv//eng)

Nyckelord

Functional joint centre
Artificial-limb
Kinematics
Marker placement

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Rusaw, David, 19 ...
Ramstrand, Nerro ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Ortopedi
Artiklar i publikationen
Clinical Biomech ...
Av lärosätet
Jönköping University

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy