SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Rådström Niklas)
 

Sökning: WFRF:(Rådström Niklas) > Bacterial changes i...

Bacterial changes in a full-scale drinking water distribution system after the removal of monochloramine

Schleich, Caroline (författare)
Vatten & Miljö i Väst AB
Gador, Niklas (författare)
Högskolan Kristianstad,Avdelningen för datavetenskap
Rådström, Peter (författare)
Lunds universitet
visa fler...
Paul, Catherine (författare)
Lunds universitet
Keucken, Alexander (författare)
Vatten & Miljö i Väst AB; Lunds universitet
visa färre...
 (creator_code:org_t)
2021
2021
Engelska.
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)
Abstract Ämnesord
Stäng  
  • Context. Changes in drinking water treatment can affect the biofilm in the drinking water distribution system (DWDS) and enhanced monitoring is recommended to guarantee drinking water safety after substantial process modifications. Ultrafiltration was introduced in 2016 to the drinking water treatment plant Kvarnagården in Varberg, Sweden, achieving total removal of bacteria cells. This improved treatment led to the decision to remove the disinfectant monochloramine in 2020. Gap. Several studies compare the bacteria in different DWDS with and without disinfectants. To minimize complicating variables, this study examined the effects of the removal of the disinfectant in a single full scale DWDS.Aim. This study describes flow cytometry (FCM) monitoring initiated to follow bacteria in the water of the DWDS during removal of monochloramine. Methods. Water samples from 15 points in the DWDS were analysed by standard FCM, with data analysis using custom scripts in R for data analysis.Findings. By comparing FCM data to baselines, distinct changes in the bacterial community were observed following removal of monochloramine. Percentages of high nucleic acid bacteria (HNA) decreased at all sampling points, from 55 – 90 % to 45 – 60 %. Total cell counts (TCC) increased only in parts of the DWDS that had been exposed to monochloramine before the removal. Principal component analysis visualized the changes (Figure 1). The bacterial community at DWDS locations that used to differ largely regarding TCC and %HNA started to become more homogenous, emphasizing the value of FCM monitoring, as these same changes were not observed with traditional heterotrophic plate counts. The bacterial communities stabilized in summer 2020 and began to follow previously observed seasonal trends.Utilization. This study demonstrated the application of FCM monitoring of the impact of monochloramine removal on bacterial water quality, and the importance of having robust baselines for multiple locations within a DWDS for comparison. 

Ämnesord

NATURAL SCIENCES  -- Biological Sciences -- Microbiology (hsv//eng)
NATURVETENSKAP  -- Biologiska vetenskaper -- Mikrobiologi (hsv//swe)
NATURVETENSKAP  -- Biologi (hsv//swe)
NATURAL SCIENCES  -- Biological Sciences (hsv//eng)

Publikations- och innehållstyp

vet (ämneskategori)
kon (ämneskategori)

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy