SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:1059 9630 OR L773:1544 1016
 

Sökning: L773:1059 9630 OR L773:1544 1016 > Failure of Multilay...

Failure of Multilayer Suspension Plasma Sprayed Thermal Barrier Coatings in the Presence of Na2SO4 and NaCl at 900 °C

Jonnalagadda, Krishna Praveen, 1988- (författare)
Linköpings universitet,Konstruktionsmaterial,Tekniska fakulteten
Mahade, Satyapal, 1987- (författare)
Högskolan Väst,Avdelningen för avverkande och additativa tillverkningsprocesser (AAT),PTW,Högskolan Väst, Avdelningen för avverkande och additativa tillverkningsprocesser (AAT)
Kramer, Stephanie (författare)
Linköpings universitet,Institutionen för ekonomisk och industriell utveckling,Tekniska fakulteten
visa fler...
Zhang, Pimin, 1990- (författare)
Linköpings universitet,Konstruktionsmaterial,Tekniska fakulteten
Curry, Nicholas (författare)
Treibacher Industrie AG, Althofen, Austria
Li, Xin-Hai (författare)
Siemens Industrial Turbomachinery AB, Finspång, Sweden
Peng, Ru Lin, 1960- (författare)
Linköpings universitet,Konstruktionsmaterial,Tekniska fakulteten
visa färre...
 (creator_code:org_t)
2018-10-29
2019
Engelska.
Ingår i: Journal of thermal spray technology (Print). - : Springer Science and Business Media LLC. - 1059-9630 .- 1544-1016. ; 28:1-2, s. 212-222
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The current investigation focuses on understanding the influence of a columnar microstructure and a sealing layer on the corrosion behavior of suspension plasma sprayed thermal barrier coatings (TBCs). Two different TBC systems were studied in this work. First is a double layer made of a composite of gadolinium zirconate + yttria stabilized zirconia (YSZ) deposited on top of YSZ. Second is a triple layer made of dense gadolinium zirconate deposited on top of gadolinium zirconate + YSZ over YSZ. Cyclic corrosion tests were conducted between 25 and 900 °C with an exposure time of 8 h at 900 °C. 75 wt.% Na2SO4 + 25 wt.% NaCl were used as the corrosive salts at a concentration of 6 mg/cm2. Scanning electron microscopy analysis of the samples’ cross sections showed that severe bond coat degradation had taken place for both the TBC systems, and the extent of bond coat degradation was relatively higher in the triple-layer system. It is believed that the sealing layer in the triple-layer system reduced the number of infiltration channels for the molten salts which resulted in overflowing of the salts to the sample edges and caused damage to develop relatively more from the edge.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Materialteknik -- Bearbetnings-, yt- och fogningsteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Materials Engineering -- Manufacturing, Surface and Joining Technology (hsv//eng)

Nyckelord

columnar microstructure
composite of gadolinium zirconate and YSZ
hot corrosion
suspension plasma spray
Manufacturing and materials engineering
Produktions- och materialteknik
Production Technology
Produktionsteknik

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy