SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:kth-107103"
 

Sökning: onr:"swepub:oai:DiVA.org:kth-107103" > Sign-Dependent Sens...

Sign-Dependent Sensitivity to Peripheral Defocus for Myopes due to Aberrations

Rosén, Robert (författare)
KTH,Biomedicinsk fysik och röntgenfysik
Lundström, Linda (författare)
KTH,Biomedicinsk fysik och röntgenfysik
Unsbo, Peter (författare)
KTH,Biomedicinsk fysik och röntgenfysik
 (creator_code:org_t)
Association for Research in Vision and Ophthalmology (ARVO), 2012
2012
Engelska.
Ingår i: Investigative Ophthalmology and Visual Science. - : Association for Research in Vision and Ophthalmology (ARVO). - 0146-0404 .- 1552-5783. ; 53:11, s. 7176-7182
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • PURPOSE. Animal studies suggest that the periphery of the eye plays a major role in emmetropization. It is also known that human myopes tend to have relative peripheral hyperopia compared to the foveal refraction. This study investigated peripheral sensitivity to defocus in human subjects, specifically whether myopes are less sensitive to negative than to positive defocus. METHODS. Sensitivity to defocus (logMAR/D) in the 20 degrees nasal visual field was determined in 16 emmetropes (6 males and 10 females, mean spherical equivalent -0.03 +/- 0.13 D, age 30 +/- 6 10 years) and 16 myopes (3 males and 13 females, mean spherical equivalent -3.25 +/- 2 D, age 25 +/- 6 years) using the slope of through-focus low-contrast resolution (10%) acuity measurements. Peripheral wavefront measurements at the same angle were obtained from 13 of the myopes and 9 of the emmetropes, from which the objective depth of field was calculated by assessing the area under the modulation transfer function (MTF) with added defocus. The difference in depth of field between negative and positive defocus was taken as the asymmetry in depth of field. RESULTS. Myopes were significantly less sensitive to negative than to positive defocus (median difference in sensitivity 0.06 logMAR/D, P = 0.023). This was not the case for emmetropes (median difference -0.01 logMAR/D, P = 0.382). The difference in sensitivity between positive and negative defocus was significantly larger for myopes compared to emmetropes (P = 0.031). The correlation between this difference in sensitivity and objective asymmetry in depth of field due to aberrations was significant for the whole group (R-2 = 0.18, P 0.02) and stronger for myopes (R-2 = 0.8, P < 0.01). CONCLUSIONS. We have shown that myopes, in general, are less sensitive to negative than to positive defocus, which can be linked to their aberrations. This finding is consistent with a previously proposed model of eye growth that is driven by the difference between tangential and radial peripheral blur.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Oftalmologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Ophthalmology (hsv//eng)

Nyckelord

Depth-Of-Field
Refractive Error
Human Eye
Optical-Quality
Monochromatic Aberrations
Visual-Field
Children
Vision
Lenses
Growth

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Rosén, Robert
Lundström, Linda
Unsbo, Peter
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Oftalmologi
Artiklar i publikationen
Investigative Op ...
Av lärosätet
Kungliga Tekniska Högskolan

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy