Biomechanics of the Human Eye and Intraocular Pressure Measurements

Ljubimova, Darja, 1981- (author)
KTH,Strukturmekanik
Eriksson, Anders, Professor (thesis advisor)
KTH,Mekanik
Eklund, Anders, Docent (opponent)
Strålningsvetenskaper, Umeå universitet
 (creator_code:org_t)
Stockholm : KTH, 2009
English xvi, 200 s.
Series: Trita-MEK, 0348-467X ; 2009:10
  • Doctoral thesis (other academic/artistic)
Abstract Subject headings
Close  
  • This thesis addresses the reliability of Goldmann-type applanation tonometers (GAT). It deals with the investigation of the relation between predicted intraocular pressure, IOPG and true pressure, IOPT. The problem of the accuracy of GAT readings has acquired special importance over the last two decades as new types of surgical procedures to correct vision disorders are being explored and gain universal acceptance. The overall aim of the present study is to assess the effects of individual variations in the corneal central thickness (CCT), material properties of the involved tissues and paracentral applanation on the accuracy of IOPG. Two finite element models have been constructed: a two-dimensional axisymmetric model of the cornea and a three-dimensional model of the whole corneoscleral envelope. Various material descriptions were adopted for the cornea in 2D, whereas the 3D model accounted for collagen microstructure and represented a hyperelastic ber reinforced material. Nonlinear analyses were carried out using the commercial general-purpose finite element software ABAQUS. An extensive literature survey and consultations with ophthalmologists and clinicians were the platform for establishing relevant modelling procedures. The results reveal a clear association between all considered parameters and measured IOPG. The effect of assumed CCT is highly dependent on the corneal material properties. Material model alone has a profound effect on predicted IOPG. Variations in tonometer tip application produce clinically signi cant errors to IOPG measurements. Potential effects of corneal stiffness and paracentral applanation on GAT readings are larger than the impact of CCT. The behaviour of the models is broadly in agreement with published observations. The proposed procedures can be a useful tools for suggesting the magnitudes of corrections for corneal biomechanics and possible human errors. The present modelling exercise has an ability to reproduce the behaviour of human cornea and trace it under IOP and GAT, providing potentially useful information on the distribution of stresses and strains. Some recommendations can be drawn in pursuit of the clinical imperatives of ophthalmologists.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering (hsv//eng)

Keyword

IOP
GAT
ocular biomechanics
corneoscleral envelope
finite element modelling
parametric analysis
Engineering mechanics
Teknisk mekanik

Publication and Content Type

vet (subject category)
dok (subject category)

Find in a library

To the university's database

Find more in SwePub

By the author/editor
Ljubimova, Darja ...
Eriksson, Anders ...
Eklund, Anders, ...
About the subject
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Mechanical Engin ...
Parts in the series
Trita-MEK,
By the university
Royal Institute of Technology

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view