Reflection properties of a flow pipe with a small angle diffuser outlet

Boij, Susann (författare)
KTH,MWL Marcus Wallenberg Laboratoriet
Åbom, Mats (författare)
KTH,MWL Marcus Wallenberg Laboratoriet
Pieters, R. (författare)
Eindhoven University of Technology, Department of Applied Physics, Netherlands
 (creator_code:org_t)
2010
2010
Engelska.
Ingår i: 17th International Congress on Sound and Vibration 2010, ICSV 2010. - 9781617822551 ; , s. 706-712
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • The reflection of plane acoustic waves is studied for an open pipe termination where the outlet section about 10 cm long is a diffuser with a small angle. Diffuser angles up to 6o with a sharp outlet edge are considered both without and with a mean flow. The experiments are performed for Helmholtz numbers, He, based on the pipe diameter, up to 1.0 and mean flow Mach numbers, M, up to 0.25. A multi-microphone method is used for accurate measurements of the acoustic fields inside the pipe. With no mean flow, the reflection coefficient results are compared with the theories for thin walls by Levine and Schwinger [1] and for the end correction and thick walls by Ando [2], respectively. The data for the magnitude of the reflection coefficient for different pipe end geometries show that in the low frequency regime it is the outlet radius that determines the magnitude of the energy reflection coefficient. The same collapse in the data is not obtained for the end correction which is strongly affected by the pipe end geometry. Experimental results of the reflection coefficient in the presence of a mean flow show a similar behaviour as without flow. However, it is the Strouhal number of the outlet that governs the losses, i.e., radiation and flow losses. For a region of small Strouhal numbers, the reflection is larger than one, as predicted for straight pipes, [3, 4]. An increased diffuser angle and rounded edges both increase the reflection at the pipe termination in a critical range of Strouhal numbers, which indicates that the reflection coefficient is strongly dependent on the shape, half angle, and edge curvature of the pipe end in this region.

Nyckelord

Accurate measurement
Diffuser angle
Energy reflection coefficients
Flow loss
Frequency regimes
Helmholtz number
Mean flow
Pipe diameter
Plane acoustic waves
Reflection properties
Rounded edge
Straight pipe
Thick-wall
Thin walls
Acoustic fields
Ducted fan engines
Mach number
Strouhal number
Reflection

Publikations- och innehållstyp

ref (ämneskategori)
kon (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Boij, Susann
Åbom, Mats
Pieters, R.
Artiklar i publikationen
17th Internation ...
Av lärosätet
Kungliga Tekniska Högskolan

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy