The influence of bis-EMA vs bis GMA on the degree of conversion and water susceptibility of experimental composite materials

Cornelio, Roberto Belloti (författare)
Wikant, Aksel (författare)
Mjosund, Hanne (författare)
visa fler...
Kopperud, Hilde Molvig (författare)
Haasum, Johan (författare)
KTH,Fiber- och polymerteknologi
Gedde, Ulf (författare)
KTH,Fiber- och polymerteknologi
Ortengren, Ulf Thore (författare)
visa färre...
 (creator_code:org_t)
2013-11-21
2014
Engelska.
Ingår i: Acta Odontologica Scandinavica. - : Informa UK Limited. - 0001-6357 .- 1502-3850. ; 72:6, s. 440-447
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Objective. The aim of this work was to assess the influence of the bis-EMA content on the degree of conversion (DC) and its effect on the water sorption and solubility. Materials and methods. In a polytetrafluorethylene (PTFE) mould, 30 samples (O = 5 mm, height = 2 mm) of four experimental dental composite resins were cured for 10 s, 20 s and 40 s. The DC was analysed by Fourier Transform (FT)-Raman spectroscopy. To analyse sorption and solubility, six samples (O = 15 mm and thickness = 1 mm) of each composite (n = 72) were stored in water at 37 degrees C for different storage periods: 24 h, 7 days and 30 days. Results. When cured for 20 or 40 s the DC increased with the increasing content of bis-EMA. However, the presence of 15 wt% of bis-GMA did not affect the DC, except when cured with 10 s irradiation time. This study also found a correlation between the content of bis-EMA and the reduced values for sorption and solubility, for all storage times used, when the materials were cured with 20 s. Conclusions. The DC of mixtures with higher content of bis-EMA is affected by the presence of bis-GMA at lower energy density delivered from the curing device, suggesting that the restrictions caused by the presence of hydrogen bonds is dependent of the irradiation time used.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)
NATURVETENSKAP  -- Kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences (hsv//eng)

Nyckelord

dental composites
bis-EMA
hydrogen bonds
energy density
FT-Raman spectroscopy

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy