SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:kth-157573"
 

Sökning: id:"swepub:oai:DiVA.org:kth-157573" > Point-of-Care Verti...

  • Chinnasamy, ThiruppathirajaKTH,Proteomik och nanobioteknologi,Science for Life Laboratory, SciLifeLab (författare)

Point-of-Care Vertical Flow Allergen Microarray Assay : Proof of Concept

  • Artikel/kapitelEngelska2014

Förlag, utgivningsår, omfång ...

  • 2014-09-01
  • Oxford University Press (OUP),2014
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:kth-157573
  • https://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-157573URI
  • https://doi.org/10.1373/clinchem.2014.223230DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • QC 20141215
  • BACKGROUND: Sophisticated equipment, lengthy protocols, and skilled operators are required to perform protein microarray-based affinity assays. Consequently, novel tools are needed to bring biomarkers and biomarker panels into clinical use in different settings. Here, we describe a novel paper-based vertical flow microarray (VFM) system with a multiplexing capacity of at least 1480 microspot binding sites, colorimetric readout, high sensitivity, and assay time of < 10 min before imaging and data analysis. METHOD: Affinity binders were deposited on nitrocellulose membranes by conventional microarray printing. Buffers and reagents were applied vertically by use of a flow controlled syringe pump. As a clinical model system, we analyzed 31 precharacterized human serum samples using the array system with 10 allergen components to detect specific IgE reactivities. We detected bound analytes using gold nanoparticle conjugates with assay time of <= 10 min. Microarray images were captured by a consumer-grade flatbed scanner. RESULTS: A sensitivity of 1 ng/mL was demonstrated with the VFM assay with colorimetric readout. The reproducibility (CV) of the system was < 14%. The observed concordance with a clinical assay, Immuno-CAP, was R-2 = 0.89 (n = 31). CONCLUSIONS: In this proof-of-concept study, we demonstrated that the VFM assay, which combines features from protein microarrays and paper-based colorimetric systems, could offer an interesting alternative for future highly multiplexed affinity point-of-care testing.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Segerink, Loes I. (författare)
  • Nystrand, Mats (författare)
  • Gantelius, JesperKTH,Proteomik och nanobioteknologi,Science for Life Laboratory, SciLifeLab(Swepub:kth)u15pw7ne (författare)
  • Andersson Svahn, HeleneKTH,Proteomik och nanobioteknologi,Science for Life Laboratory, SciLifeLab(Swepub:kth)u1706qv6 (författare)
  • KTHProteomik och nanobioteknologi (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Clinical Chemistry: Oxford University Press (OUP)60:9, s. 1209-12160009-91471530-8561

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy