SwePub
Sök i LIBRIS databas

  Utökad sökning

hsv:(ENGINEERING AND TECHNOLOGY) hsv:(Medical Engineering) hsv:(Medical Materials)
 

Sökning: hsv:(ENGINEERING AND TECHNOLOGY) hsv:(Medical Engineering) hsv:(Medical Materials) > Unique pumping-out ...

Unique pumping-out fracturing mechanism of a polymer-shelled contrast agent : An acoustic characterization and optical visualization

Kothapalli, Veera Venkata Satya Naray, 1985- (författare)
KTH,Medicinsk bildteknik,Contrast Enhanced Medical Imaging
Daeichin, Verya (författare)
Department of Biomedical Engineering, Thoraxcenter, Erasmus MC,
Mastik, Frits (författare)
Department of Biomedical Engineering, Thoraxcenter, Erasmus MC
visa fler...
Brodin, Lars-Åke (författare)
KTH,Medicinsk bildteknik
Janerot Sjöberg, Birgitta (författare)
KTH,Medicinsk teknik,Karolinska Institutet, Sweden; Karolinska University Hospital, Sweden
Paradossi, Gaio (författare)
Diapartimento di Chimica, Università di Roma Tor Vergata
de Jong, N. (författare)
Department of Biomedical Engineering, Thoraxcenter, Erasmus MC
Grishenkov, Dmitry, 1983- (författare)
KTH,Medicinsk bildteknik,Karolinska Institutet, Sweden; Karolinska University Hospital, Sweden,Contrast Enhanced Medical Imaging
visa färre...
 (creator_code:org_t)
2014
2014
Engelska.
Ingår i: IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control. - 0885-3010 .- 1525-8955. ; 62:3, s. 451-462
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • This work describes the fracturing mechanism of air-filled microbubbles (MBs) encapsulated by a cross-linked poly(vinyl alcohol) (PVA) shell. The radial oscillation and fracturing events following the ultrasound exposure were visualized with an ultrahigh-speed camera, and backscattered timedomain signals were acquired with the acoustic setup specific for harmonic detection. No evidence of gas emerging from defects in the shell with the arrival of the first insonation burst was found. In optical recordings, more than one shell defect was noted, and the gas core was drained without any sign of air extrusion when several consecutive bursts of 1 MPa amplitude were applied. In acoustic tests, the backscattered peak-to-peak voltage gradually reached its maximum and exponentially decreased when the PVA-based MB suspension was exposed to approximately 20 consecutive bursts arriving at pulse repetition frequencies of 100 and 500 Hz. Taking into account that the PVA shell is porous and possibly contains large air pockets between the cross-linked PVA chains, the aforementioned acoustic behavior might be attributed to pumping gas from these pockets in combination with gas release from the core through shell defects. We refer to this fracturing mechanism as pumping-out behavior, and this behavior could have potential use for the local delivery of therapeutic gases, such as nitric oxide.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk apparatteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Equipment Engineering (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Image Processing (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk material- och protesteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Materials (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy