SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Collaboration A. T. L. A. S.)
 

Sökning: WFRF:(Collaboration A. T. L. A. S.) > (2005-2009) > Performance of HPGe...

Performance of HPGe detectors in high magnetic fields

Lorente, A. Sanchez (författare)
Achenbach, P. (författare)
Agnello, M. (författare)
visa fler...
Bressani, T. (författare)
Bufalino, S. (författare)
Cederwall, Bo (författare)
KTH,Kärnfysik
Feliciello, A. (författare)
Ferro, F. (författare)
Gerl, J. (författare)
Iazzi, F. (författare)
Kavatsyuk, M. (författare)
Kojouharov, I. (författare)
Majling, L. (författare)
Pantaleo, A. (författare)
Palomba, M. (författare)
Pochodzalla, J. (författare)
Raciti, G. (författare)
Saito, N. (författare)
Saito, T. R. (författare)
Schaffner, H. (författare)
Sfienti, C. (författare)
Szymanska, K. (författare)
Tegner, Per - Erik (författare)
Stockholms universitet,Fysikum
HyperGamma, Collaboration (författare)
visa färre...
 (creator_code:org_t)
Elsevier BV, 2007
2007
Engelska.
Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 573:3, s. 410-417
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • A new generation of high-resolution hypernuclear gamma-spectroscopy experiments with high-purity germanium detectors (HPGe) are presently designed at the FINUDA spectrometer at DA Phi NE, the Frascati phi-factory, and at (P) over bar ANDA, the (p) over barp hadron spectrometer at the future FAIR facility. Both, the FINUDA and (P) over bar ANDA spectrometers are built around the target region covering a large solid angle. To maximise the detection efficiency the HPGe detectors have to be located near the target, and therefore they have to be operated in strong magnetic fields (B approximate to I T). The performance of HPGe detectors in such an environment has not been well investigated so far. In the present work VEGA and EUROBALL Cluster HPGe detectors were tested in the field provided by the ALADiN magnet at GSI. No significant degradation of the energy resolution was found, and a change in the rise time distribution of the pulses from preamplifiers was observed. A correlation between rise time and pulse height was observed and is used to correct the measured energy, recovering the energy resolution almost completely. Moreover, no problems in the electronics due to the magnetic field were observed.

Ämnesord

NATURVETENSKAP  -- Fysik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences (hsv//eng)

Nyckelord

hypernuclear gamma-spectroscopy
HPGe detectors
germanium detectors
ge detectors
silicon
spectroscopy
hypernuclei
transition
Physics

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy