SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Örtqvist Eva)
 

Sökning: WFRF:(Örtqvist Eva) > Reliability of a ne...

Reliability of a new instrument for measuring plantarflexor muscle strength

Örtqvist, Maria (författare)
Karolinska Institutet
Gutierrez-Farewik, Elena M. (författare)
Karolinska Institutet,KTH,Mekanik
Farewik, Markus (författare)
KTH
visa fler...
Jansson, Anna (författare)
Bartonek, Åsa (författare)
Karolinska Institutet
Broström, Eva (författare)
Karolinska Institutet
visa färre...
 (creator_code:org_t)
Elsevier BV, 2007
2007
Engelska.
Ingår i: Archives of Physical Medicine and Rehabilitation. - : Elsevier BV. - 0003-9993 .- 1532-821X. ; 88:9, s. 1164-1170
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Objectives: To test the reliability of a new muscle strength testing instrument (the Strength Measuring Chair [SMC]) designed to quantify isometric strength in the lower extremities, and to determine the agreement between the SMC and an isokinetic dynamometer (Biodex). Design: Isometric strength tests were performed in plantar-flexors with 2 different knee positions (60 degrees, 30 degrees). Measurements were taken at 3 different sessions. Setting: Strength testing laboratory. Participants: Twenty-three able-bodied adults and 15 able-bodied children. Interventions: Not applicable. Main Outcome Measure: Isometric plantarflexor strength. Results: The reliability of isometric strength measurements of plantarflexors taken in the SMC was excellent for both the adult and children groups (intraclass correlation coefficient range,.84-.87). A Bland-Altman 95% limit of agreement test showed no systematic variation in 3 of the 4 SMC test observations; systematic variation was only observed in the adult group at a knee position of 30 degrees. There was no systematic difference in the adult group between the SMC and the isokinetic dynamometer, but there was a systematic variation in the children's group. Conclusions: The SMC reliably measured isometric plantarflexor strength in the tested populations.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering (hsv//eng)

Nyckelord

gastrocnemius muscle
isometric contraction
rehabilitation
reproducibility of results
soleus muscle
hand-held dynamometry
interrater reliability
isokinetic dynamometer
cerebral-palsy
children
torque
knee
activation
arthritis
velocity

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy