SwePub
Sök i LIBRIS databas

  Extended search

WFRF:(Niklaus Frank)
 

Search: WFRF:(Niklaus Frank) > Hydrophobic valves ...

Hydrophobic valves of plasma deposited octafluorocyclobutane in DRIE channels

Andersson, Helene (author)
KTH,Bioteknologi
van der Wijngaart, Wouter (author)
KTH,Signaler, sensorer och system
Griss, P. (author)
show more...
Niklaus, Frank (author)
KTH,Signaler, sensorer och system
Stemme, Göran (author)
KTH,Signaler, sensorer och system
show less...
 (creator_code:org_t)
2001
2001
English.
In: Sensors and actuators. B, Chemical. - 0925-4005 .- 1873-3077. ; 75:1-2, s. 136-141
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • The suitability of using octafluorocyclobutane (C4F8) patches as hydrophobic valves in microfluidic biochemical applications has been shown. A technique has been developed to generate lithographically defined C4F8 hydrophobic patches in deep reactive ion-etched silicon channels. Some of the advantages of this process are that no specific cleaning of the substrate is required, C4F8 is deposited on the sidewalls and the bottom of the channels, a standard photoresist mask can be used to define the patches, and that it is a fast and convenient dry chemical process performed by a standard inductively coupled plasma etcher using the Bosch process. Different patch lengths (200-1000 mum) of C4F8 were deposited in 50 mum wide channels to evaluate which size is most suitable for microfluidic biochemical applications. The valve function of the hydrophobic patches was tested for the following liquids: DD water, acetone, propanol, bead solution and a mixture used for pyrosequencing of DNA. Patch lengths of 200 mum of C4F8 successfully stopped each solution for at least 20 consecutive times. The C4F8 film resists water for at least 5 h. The hydrophobic valve also resists very high concentrations (25%) of surfactants (Tween 80). C4F8 shows a much higher resistance towards water and surface active solutions than previous hydrophobic patches. However, 50% Tween 80 was not stopped at all by the hydrophobic patch. An applied pressure of 760 Pa at the inlet was needed for water to over-run the hydrophobic patch.

Keyword

passive valve
liquid control
fluorocarbon
capillary tilling
microfluidics

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view