SwePub
Sök i LIBRIS databas

  Extended search

WFRF:(Linnros Jan)
 

Search: WFRF:(Linnros Jan) > Improvement of an X...

Improvement of an X-ray imaging detector based on a scintillating guides screen

Badel, Xavier (author)
KTH,Mikroelektronik och informationsteknik, IMIT
Galeckas, Augustinas (author)
KTH,Mikroelektronik och informationsteknik, IMIT
Linnros, Jan (author)
KTH,Mikroelektronik och informationsteknik, IMIT
show more...
Kleimann, P. (author)
LENAC, Université Claude Bernard Lyon-I, Villeurbanne,KTH
Fröjdh, Christer, 1952- (author)
Mittuniversitetet,Institutionen för informationsteknologi och medier (-2013)
Petersson, C. Sture (author)
Mittuniversitetet,KTH,Mikroelektronik och informationsteknik, IMIT,Institutionen för informationsteknologi och medier (-2013)
show less...
 (creator_code:org_t)
2002
2002
English.
In: Nuclear Instruments and Methods in Physics Research Section A. - 0168-9002 .- 1872-9576. ; 487:1-2, s. 129-135
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • An X-ray imaging detector has been developed for dental applications. The principle of this detector is based on application of a silicon charge coupled device covered by a scintillating wave-guide screen. Previous studies of such a detector showed promising results concerning the spatial resolution but low performance in terms of signal to noise ratio (SNR) and sensitivity. Recent results confirm the wave-guiding properties of the matrix and show improvement of the detector in terms of response uniformity, sensitivity and SNR. The present study is focussed on the fabrication of the scintillating screen where the principal idea is to fill a matrix of Si pores with a CsI scintillator. The photoluminescence technique was used to prove the wave-guiding property of the matrix and to inspect the filling uniformity of the pores. The final detector was characterized by X-ray evaluation in terms of spatial resolution, light output and SNR. A sensor with a spatial resolution of 9 LP/mm and a SNR over 50 has been achieved using a standard dental X-ray source and doses in the order of those used at the moment by dentists (around 25 mR).

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik -- Annan elektroteknik och elektronik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering -- Other Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)

Keyword

dental imaging
pixel detector
scintillating screen
CsI(Tl)
X-rays
silicon
pores
Electrophysics
Elektrofysik
Electrical engineering, electronics and photonics

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view