SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:kth-22200"
 

Sökning: id:"swepub:oai:DiVA.org:kth-22200" > Evaluation of a seg...

  • Qatarneh, Sharif M.Stockholms universitet,Medicinsk strålningsfysik (tills m KI) (författare)

Evaluation of a segmentation procedure to delineate organs for use in construction of a radiation therapy planning atlas

  • Artikel/kapitelEngelska2003

Förlag, utgivningsår, omfång ...

  • 2003
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:kth-22200
  • https://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-22200URI
  • https://doi.org/10.1016/S1386-5056(02)00079-5DOI
  • http://kipublications.ki.se/Default.aspx?queryparsed=id:1931896URI
  • https://urn.kb.se/resolve?urn=urn:nbn:se:su:diva-25307URI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • QC 20100525 NR 20140804
  • Objectives: This paper evaluates a semi-automatic segmentation procedure to enhance utilizing atlas based treatment plans. For this application, it is crucial to provide a collection of 'reference' organs, restorable from the atlas so that they closely match those of the current patient. To enable assembling representative organs, we developed a semiautomatic procedure using an active contour method. Method: The 3D organ volume was identified by defining contours on individual slices. The initial organ contours were matched to patient volume data sets and then superimposed on them. These starting contours were then adjusted and refined to rapidly find the organ outline of the given patient. Performance was evaluated by contouring organs of different size, shape complexity, and proximity to surrounding structures. We used representative organs defined on CT volumes obtained from 12 patients and compared the resulting outlines to those drawn by a radiologist. Results: A strong correlation was found between the area measures of the delineated liver (r = 0.992), lung (r = 0.996) and spinal cord (r = 0.81), obtained by both segmentation techniques. A paired Student's t-test showed no statistical difference between the two techniques regarding the liver and spinal cord (p > 0.05). Conclusion: This method could be used to form 'standard' organs, which would form part of a whole body atlas (WBA) database for radiation treatment plans as well as to match atlas organs to new patient data.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Noz, Marilyn E.New York University, Department of Radiology,Nuclear Medicine (författare)
  • Hyodynmaa, SimoTampere Univ Hosp, Dept Oncol, Tampere, Finland (författare)
  • Maguire Jr., Gerald Q.KTH,Mikroelektronik och informationsteknik, IMIT(Swepub:kth)u1d13i2c (författare)
  • Kramer, Elissa L.New York University, Department of Radiology (författare)
  • Crafoord, JoakimDepartment of Radiology, Karolinska Hospital (författare)
  • Stockholms universitetMedicinsk strålningsfysik (tills m KI) (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:International Journal of Medical Informatics69, s. 39-551386-50561872-8243
  • Ingår i:International Journal of Medical Informatics69, s. 39-55

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy