Advancing the immunoaffinity platform AFFIRM to targeted measurements of proteins in serum in the pg/ml range
-
- Säll, Anna (författare)
- Lund University,Lunds universitet,Institutionen för immunteknologi,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Immunotechnology,Departments at LTH,Faculty of Engineering, LTH
-
- Corbee, Daniel (författare)
- Lund Univ, Dept Immunotechnol, Lund, Sweden.;Camurus, Lund, Sweden.,Lund University
-
- Vikstrom, Sara (författare)
- Lund Univ, Dept Immunotechnol, Lund, Sweden.;BioGaia AB, Lund, Sweden.,Lund University
-
visa fler...
-
- Ottosson, Filip (författare)
- Lund University,Lunds universitet,Institutionen för immunteknologi,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Immunotechnology,Departments at LTH,Faculty of Engineering, LTH
-
- Persson, Helena (författare)
- KTH Royal Institute of Technology,KTH,Industriell bioteknologi,Science for Life Laboratory, SciLifeLab,Lund Univ, Dept Immunotechnol, Lund, Sweden.
-
- Waldemarson, Sofia (författare)
- Lund University,Lunds universitet,Institutionen för immunteknologi,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Immunotechnology,Departments at LTH,Faculty of Engineering, LTH
-
visa färre...
-
(creator_code:org_t)
- 2018-02-13
- 2018
- Engelska.
-
Ingår i: PLOS ONE. - : PUBLIC LIBRARY SCIENCE. - 1932-6203. ; 13:2
- Relaterad länk:
-
https://journals.plo...
-
visa fler...
-
http://dx.doi.org/10... (free)
-
https://urn.kb.se/re...
-
https://doi.org/10.1...
-
https://lup.lub.lu.s...
-
visa färre...
Abstract
Ämnesord
Stäng
- There is a great need for targeted protein assays with the capacity of sensitive measurements in complex samples such as plasma or serum, not the least for clinical purposes. Proteomics keeps generating hundreds of biomarker candidates that need to be transferred towards true clinical application through targeted verification studies and towards clinically applicable analysis formats. The immunoaffinity assay AFFIRM (AFFInity sRM) combines the sensitivity of recombinant single chain antibodies (scFv) for targeted protein enrichment with a specific mass spectrometry readout through selected reaction monitoring (SRM) in an automated workflow. Here we demonstrate a 100 times improved detection capacity of the assay down to pg/ml range through the use of oriented antibody immobilization to magnetic beads. This was achieved using biotin-tagged scFv coupled to streptavidin coated magnetic beads, or utilizing the FLAG tag for coupling to anti-FLAG antibody coated magnetic beads. An improved multiplexing capacity with an 11-plex setup was also demonstrated compared to a previous 3-plex setup, which is of great importance for the analysis of panels of biomarker targets.
Ämnesord
- NATURVETENSKAP -- Kemi -- Analytisk kemi (hsv//swe)
- NATURAL SCIENCES -- Chemical Sciences -- Analytical Chemistry (hsv//eng)
- MEDICIN OCH HÄLSOVETENSKAP -- Medicinska och farmaceutiska grundvetenskaper -- Immunologi inom det medicinska området (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Basic Medicine -- Immunology in the medical area (hsv//eng)
- TEKNIK OCH TEKNOLOGIER -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)