SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Jacob Mina)
 

Sökning: WFRF:(Jacob Mina) > (2018) > Initial in-vitro tr...

Initial in-vitro trial for intra-cranial pressure monitoring using subdermal proximity-coupled split-ring resonator

Redzwan, Syaiful (författare)
Uppsala universitet,Fasta tillståndets elektronik
Velander, Jacob (författare)
Uppsala universitet,Fasta tillståndets elektronik
Perez, Mauricio D. (författare)
Uppsala universitet,Fasta tillståndets elektronik
visa fler...
Asan, Noor Badariah, 1984- (författare)
Uppsala universitet,Fasta tillståndets elektronik
Rajabi, Mina (författare)
KTH,Mikro- och nanosystemteknik,KTH Royal Inst Technol, Sch Elect Engn, Dept Micro & Nanosyt, Stockholm, Sweden
Niklaus, Frank, 1971- (författare)
KTH,Mikro- och nanosystemteknik,KTH Royal Inst Technol, Sch Elect Engn, Dept Micro & Nanosyt, Stockholm, Sweden
Nowinski, Daniel (författare)
Uppsala universitet,Plastikkirurgi
Lewén, Anders, 1965- (författare)
Uppsala universitet,Enblad: Neurokirurgi
Enblad, Per (författare)
Uppsala universitet,Enblad: Neurokirurgi
Augustine, Robin, 1982- (författare)
Uppsala universitet,Fasta tillståndets elektronik
visa färre...
 (creator_code:org_t)
Institute of Electrical and Electronics Engineers (IEEE), 2018
2018
Engelska.
Ingår i: IMBioc 2018 - 2018 IEEE/MTT-S International Microwave Biomedical Conference. - : Institute of Electrical and Electronics Engineers (IEEE). - 9781538659182 ; , s. 73-75
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • Intra cranial pressure (ICP) monitoring is used in treating severe traumatic brain injury (TBI) patients. All current clinical available measurement methods are invasive presenting considerable social costs. This paper presents a preliminary investigation of the feasibility of ICP monitoring using an innovative microwave-based non-invasive approach. A phantom mimicking the dielectric characteristics of human tissues of the upper part of the head at low microwave frequencies is employed together to a proof-of-concept prototype based on the proposed approach consisting in a readout system and a sub-dermally implanted passive device, both based in split ring resonator techniques. This study shows the potential of our approach to detect two opposite pressure variation stages inside the skull. The employed phantom model needs to be improved to support finer variations in the pressure and better phantom parts, principally for the skull mimic and the loss tangent of all mimics.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Annan medicinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Other Medical Engineering (hsv//eng)

Nyckelord

Biocompatible
Intra cranial pressure
Microwave technique
Split ring resonator (SRR) sensor

Publikations- och innehållstyp

ref (ämneskategori)
kon (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy