SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:1873 376X OR L773:1570 0232
 

Sökning: L773:1873 376X OR L773:1570 0232 > Reduced graphene ox...

Reduced graphene oxide as an efficient sorbent in microextraction by packed sorbent : Determination of local anesthetics in human plasma and saliva samples utilizing liquid chromatography-tandem mass spectrometry

Ahmadi, Mazaher (författare)
Bu Ali Sina Univ, Fac Chem, Hamadan, Iran.
Moein, Mohammad Mahdi (författare)
Karolinska Institutet
Madrakian, Tayyebeh (författare)
Bu Ali Sina Univ, Fac Chem, Hamadan, Iran.
visa fler...
Afkhami, Abbas (författare)
Bu Ali Sina Univ, Fac Chem, Hamadan, Iran.
Bahar, Soleiman (författare)
Univ Kurdistan, Fac Sci, Dept Chem, Sanandaj, Iran.
Abdel-Rehim, Mohamed (författare)
KTH,Material- och nanofysik,Karolinska Inst, Ctr Psychiat Res, Dept Clin Neurosci, SE-17176 Stockholm, Sweden.;Stockholm Cty Council, SE-17176 Stockholm, Sweden.
visa färre...
Karolinska Institutet Bu Ali Sina Univ, Fac Chem, Hamadan, Iran (creator_code:org_t)
ELSEVIER SCIENCE BV, 2018
2018
Engelska.
Ingår i: Journal of chromatography. B. - : ELSEVIER SCIENCE BV. - 1570-0232 .- 1873-376X. ; 1095, s. 177-182
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Herein, reduced graphene oxide (RGO) has been utilized as an efficient sorbent in microextraction by packed sorbent (MEPS). The combination of MEPS and liquid chromatography-tandem mass spectrometry has been used to develop a method for the extraction and determination of three local anesthetics (i.e. lidocaine, prilocaine, and ropivacaine) in human plasma and saliva samples. The results showed that the utilization of RGO in MEPS could minimize the matrix effect so that no interfering peaks at the retention times of the analytes or internal standard was observed. The high extraction efficiency of this method was approved by mean recoveries of 97.26-106.83% and 95.21-105.83% for the studied analytes in plasma and saliva samples, respectively. Intra- and inter-day accuracies and precisions for all analytes were in good accordance with the international regulations. The accuracy values (as percentage deviation from the nominal value) of the quality control samples were between - 2.1 to 13.9 for lidocaine, - 4.2 to 11.0 for prilocaine and between - 4.5 to - 2.4 for ropivacaine in plasma samples while the values were ranged from - 4.6 to 1.6 for lidocaine, from - 4.2 to 15.5 for prilocaine and from - 3.3 to - 2.3 for ropivacaine in human saliva samples. Lower and upper limit of quantification (LLOQ, ULOQ) were set at 5 and 2000 nmol L-1 for all of the studied drugs. The correlation coefficients values were >= 0.995. The limit of detection values were obtained 4 nmol L-1 for lidocaine and prilocaine, and 2 nmol L-1 for ropivacaine.

Ämnesord

NATURVETENSKAP  -- Kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences (hsv//eng)

Nyckelord

Local anesthetics
Microextraction by packed sorbent
Reduced graphene oxide
LC-MS/MS
Plasma
Saliva

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy