SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:kth-247120"
 

Sökning: id:"swepub:oai:DiVA.org:kth-247120" > Impulse flashover c...

  • Gomes, AshenKTH,Elkraftteknik,Universiti Putra Malaysia (författare)

Impulse flashover characteristics of oil palm trunk (OPT) veneer plywood

  • Artikel/kapitelEngelska2018

Förlag, utgivningsår, omfång ...

  • Institute of Electrical and Electronics Engineers Inc.2018
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:kth-247120
  • https://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-247120URI
  • https://doi.org/10.1109/ICLP.2018.8503332DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:kon swepub-publicationtype

Anmärkningar

  • QC 20190403
  • Oil palm is one of the largest crop industries in South East Asia, thus, it is of importance to use all parts of the Oil palm trees. Recently Oil Palm Trunks (OPT) have been used to make veneer, which can be processed to produce plywood. Even though OPT plywood doesn't have the same mechanical properties as timber, with proper treatment and adhesives during the processing of veneer to plywood, it can be made to compete with hardwood. OPT plywood has been used in various applications from wooden appliances to housing and roofing structures. These structures are at risk of surface flashovers through lightning and electrical breakdowns. However, no study has been conducted on the effects or characteristics of OPT plywood. In this paper, the effects of impulse surface flashover under different conditions on three-layered OPT plywood has been analyzed. Experiments were conducted to identify the characteristics of OPT under clean and dry, clean and wet, and contaminated surface conditions for both parallel and perpendicular fiber orientations. The 50% breakdown voltage was determined by the up and down method. Results identified the importance of the fibre orientation and the decrease in breakdown voltage under contaminants.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Lim, E. Y. (författare)
  • Islam, T. (författare)
  • Parida, M. T. (författare)
  • Choo, A. C. Y. (författare)
  • Juliana, A. H. (författare)
  • Gomes, C. (författare)
  • Gomes, A. E.Universiti Putra Malaysia (författare)
  • Kadir, M. Z. A. A. (författare)
  • KTHElkraftteknik (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:34th International Conference on Lightning Protection, ICLP 2018: Institute of Electrical and Electronics Engineers Inc.9781538666357

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy