SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Andreozzi Giovanni)
 

Sökning: WFRF:(Andreozzi Giovanni) > Phenomenological mo...

Phenomenological models of Na(V)1.5. A side by side, procedural, hands-on comparison between Hodgkin-Huxley and kinetic formalisms

Andreozzi, Emilio (författare)
Univ Naples Federico II, Dept Elect Engn & Informat Technol DIETI, Naples, Italy.;Ist Clin Sci Maugeri IRCCS, Dept Bioengn, Telese Terme Inst, Telese Terme, BN, Italy.
Carannante, Ilaria (författare)
KTH,Beräkningsvetenskap och beräkningsteknik (CST)
D'Addio, Giovanni (författare)
Ist Clin Sci Maugeri IRCCS, Dept Bioengn, Telese Terme Inst, Telese Terme, BN, Italy.
visa fler...
Cesarelli, Mario (författare)
Univ Naples Federico II, Dept Elect Engn & Informat Technol DIETI, Naples, Italy.;Ist Clin Sci Maugeri IRCCS, Dept Bioengn, Telese Terme Inst, Telese Terme, BN, Italy.
Balbi, Pietro (författare)
Ist Clin Sci Maugeri IRCCS, Lab Computat Neurophysiol, Telese Terme Inst, Telese Terme, BN, Italy.
visa färre...
Univ Naples Federico II, Dept Elect Engn & Informat Technol DIETI, Naples, Italy;Ist Clin Sci Maugeri IRCCS, Dept Bioengn, Telese Terme Inst, Telese Terme, BN, Italy. Beräkningsvetenskap och beräkningsteknik (CST) (creator_code:org_t)
2019-11-25
2019
Engelska.
Ingår i: Scientific Reports. - : Nature Publishing Group. - 2045-2322. ; 9
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Computational models of ion channels represent the building blocks of conductance-based, biologically inspired models of neurons and neural networks. Ion channels are still widely modelled by means of the formalism developed by the seminal work of Hodgkin and Huxley (HH), although the electrophysiological features of the channels are currently known to be better fitted by means of kinetic Markov-type models. The present study is aimed at showing why simplified Markov-type kinetic models are more suitable for ion channels modelling as compared to HH ones, and how a manual optimization process can be rationally carried out for both. Previously published experimental data of an illustrative ion channel (Na(V)1.5) are exploited to develop a step by step optimization of the two models in close comparison. A conflicting practical limitation is recognized for the HH model, which only supplies one parameter to model two distinct electrophysiological behaviours. In addition, a step by step procedure is provided to correctly optimize the kinetic Markov-type model. Simplified Markov-type kinetic models are currently the best option to closely approximate the known complexity of the macroscopic currents of ion channels. Their optimization can be achieved through a rationally guided procedure, and allows to obtain models with a computational burden that is comparable with HH models one.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Annan teknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Other Engineering and Technologies (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy