SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:2158 3226 OR L773:2158 3226
 

Sökning: L773:2158 3226 OR L773:2158 3226 > Effect of intensifi...

Effect of intensified cavitation using poly (vinyl alcohol) microbubbles on spray atomization characteristics in microscale

Abbasiasl, Taher (författare)
Sabanci University
Niazi, Soroush (författare)
Sabanci University
Sheibani Aghdam, Araz (författare)
Sabanci University
visa fler...
Chen, Hongjian (författare)
KTH,Medicinsk avbildning
Cebeci, Fevzi Cakmak (författare)
Sabanci University
Ghorbani, Morteza (författare)
KTH,Medicinsk avbildning,1 Sabanci University Nanote
Grishenkov, Dmitry, Associate Professor, 1983- (författare)
KTH,Medicinsk avbildning
Kosar, Ali (författare)
Sabanci University
visa färre...
 (creator_code:org_t)
American Institute of Physics (AIP), 2020
2020
Engelska.
Ingår i: AIP Advances. - : American Institute of Physics (AIP). - 2158-3226. ; 10:2
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • In this study, cavitating flows inside a transparent cylindrical nozzle with an inner diameter of 0.9 mm were visualized, and the effect of cavitation on atomization characteristics of emerging sprays was investigated. Different patterns of cavitating flows inside the nozzle were visualized using a high-speed camera. In-house codes were developed to process the captured images to study the droplet size distribution and droplet velocity in different flow regimes. The results show that cavitating flows at the microscale have significant effects on atomization characteristics of the spray. Two working fluids, namely, water and poly(vinyl alcohol) microbubble (PVA MB) suspension, were employed. Accordingly, the injection pressures were detected as 690 kPa, 1035 kPa, and 1725 kPa for cavitation inception, supercavitation, and hydraulic flip flow regimes in the case of water, respectively. The corresponding pressures for the aforementioned patterns for PVA MB suspension were 590 kPa, 760 kPa, and 1070 kPa, respectively. At the microscale, as a result of a higher volume fraction of cavitation bubbles inside the nozzle, there is no large difference between the cavitation numbers corresponding to cavitating and hydraulic flip flows. Although the percentage of droplets with diameters smaller than 200 μm was roughly the same for both cases of water and PVA MB suspension, the Sauter mean diameter was considerably lower in the case of PVA MBs. Moreover, higher droplet velocities were achieved in the case of PVA MBs at lower injection pressures.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Strömningsmekanik och akustik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Fluid Mechanics and Acoustics (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy