SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Setterwall Fredrik)
 

Sökning: WFRF:(Setterwall Fredrik) > Phase-Changing Glau...

Phase-Changing Glauber Salt Solution for Medical Applications in the 28-32 degrees C Interval

Olson, Linus (författare)
Karolinska Institutet
Lothian, Carina (författare)
Stockholm Soder Hosp, Neonatal Unit, S-11883 Stockholm, Sweden.
Åden, Ulrika (författare)
Karolinska Institutet
visa fler...
Lagercrantz, Hugo (författare)
Karolinska Inst, Dept Womens & Childrens Hlth, S-17177 Stockholm, Sweden.
Robertson, Nicola J. (författare)
UCL, Inst Womens Hlth, London W E 6HU, England.
Setterwall, Fredrik (författare)
KTH,Energiprocesser
visa färre...
Karolinska Institutet Stockholm Soder Hosp, Neonatal Unit, S-11883 Stockholm, Sweden (creator_code:org_t)
2021-11-23
2021
Engelska.
Ingår i: Materials. - : MDPI AG. - 1996-1944. ; 14:23
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • (1) Background: The field of medicine requires simple cooling materials. However, there is little knowledge documented about phase change materials (PCM) covering the range of 28 to 40 degrees Celsius, as needed for medical use. Induced mild hypothermia, started within 6 h after birth, is an emerging therapy for reducing death and severe disabilities in asphyxiated infants. Currently, this hypothermia is accomplished with equipment that needs a power source and a liquid supply. Neonatal cooling is more frequent in low-resource settings, where ~1 million deaths are caused by birth-asphyxia. (2) Methods: A simple and safe cooling method suitable for medical application is needed for the 28 to 37.5 degrees C window. (3) Results: Using empirical experiments in which the ingredients in Glauber salt were changed, we studied the effects of temperature on material in the indicated temperature range. The examination, in a controlled manner, of different mixtures of NaCl, Na2SO4 and water resulted in a better understanding of how the different mixtures act and how to compose salt solutions that can satisfy clinical cooling specifications. (4) Conclusions: Our Glauber salt solution is a clinically suited PCM in the temperature interval needed for the cooling of infants suffering from asphyxia.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Energiteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Energy Engineering (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Produktionsteknik, arbetsvetenskap och ergonomi (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Production Engineering, Human Work Science and Ergonomics (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Naturresursteknik -- Energisystem (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Environmental Engineering -- Energy Systems (hsv//eng)

Nyckelord

glauber salt
phase change material
neonatal asphyxia
hypoxic ischemic encephalopathy
therapeutic hypothermia

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

  • Materials (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy