Sökning: AMNE:(TEKNIK OCH TEKNOLOGIER Industriell bioteknik Medicinsk bioteknik) >
Effect of storage a...
Effect of storage and preconditioning of healing rat Achilles tendon on structural and mechanical properties
-
- Dietrich, Franciele (författare)
- Linköpings universitet,Linköping University,Avdelningen för kirurgi, ortopedi och onkologi,Medicinska fakulteten
-
- Hammerman, Malin (författare)
- Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH,Lund Univ, Sweden
-
- Bernhardsson, Magnus (författare)
- Linköpings universitet,Linköping University,Avdelningen för kirurgi, ortopedi och onkologi,Medicinska fakulteten
-
visa fler...
-
- Eliasson, Pernilla T. (författare)
- Linköpings universitet,Linköping University,Avdelningen för kirurgi, ortopedi och onkologi,Medicinska fakulteten
-
visa färre...
-
(creator_code:org_t)
- 2021-01-13
- 2021
- Engelska.
-
Ingår i: Scientific Reports. - : Springer Science and Business Media LLC. - 2045-2322. ; 11:1
- Relaterad länk:
-
http://dx.doi.org/10... (free)
-
visa fler...
-
https://www.nature.c...
-
https://liu.diva-por... (primary) (Raw object)
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
https://urn.kb.se/re...
-
visa färre...
Abstract
Ämnesord
Stäng
- Tendon tissue storage and preconditioning are often used in biomechanical experiments and whether this generates alterations in tissue properties is essential to know. The effect of storage and preconditioning on dense connective tissues, like tendons, is fairly understood. However, healing tendons are unlike and contain a loose connective tissue. Therefore, we investigated if storage of healing tendons in the fridge or freezer changed the mechanical properties compared to fresh tendons, using a pull-to-failure or a creep test. Tissue morphology and cell viability were also evaluated. Additionally, two preconditioning levels were tested. Rats underwent Achilles tendon transection and were euthanized 12 days postoperatively. Statistical analyzes were done with one-way ANOVA or Student’s t-test. Tissue force and stress were unaltered by storage and preconditioning compared to fresh samples, while high preconditioning increased the stiffness and modulus (p ≤ 0.007). Furthermore, both storage conditions did not modify the viscoelastic properties of the healing tendon, but altered transverse area, gap length, and water content. Cell viability was reduced after freezing. In conclusion, preconditioning on healing tissues can introduce mechanical data bias when having extensive tissue strength diversity. Storage can be used before biomechanical testing if structural properties are measured on the day of testing.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Medicinsk bioteknologi -- Biomaterialvetenskap (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Medical Biotechnology -- Biomaterials Science (hsv//eng)
- MEDICIN OCH HÄLSOVETENSKAP -- Medicinsk bioteknologi -- Medicinsk bioteknologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Medical Biotechnology -- Medical Biotechnology (hsv//eng)
- TEKNIK OCH TEKNOLOGIER -- Industriell bioteknik -- Medicinsk bioteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Industrial Biotechnology -- Medical Biotechnology (hsv//eng)
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas