Spectroelectrochemistry with Ultrathin lon-Selective Membranes : Three Distinct Ranges for Analytical Sensing

Liu, Yujie (författare)
KTH,Kemi
Crespo, Gaston A., 1980- (författare)
KTH,Tillämpad fysikalisk kemi
Cuartero, Maria, PhD, 1984- (författare)
KTH,Tillämpad fysikalisk kemi
 (creator_code:org_t)
2022-06-10
2022
Engelska.
Ingår i: Analytical Chemistry. - : American Chemical Society (ACS). - 0003-2700 .- 1520-6882. ; 94:25, s. 9140-9148
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • We present spectroelectrochemical sensing of the potassium ion (K+) at three very distinct analytical ranges-nanomolar, micromolar, and millimolar-when using the same ion-selective electrode (ISE) but interrogated under various regimes. The ISE is conceived in the all-solid-state format: an ITO glass modified with the conducting polymer poly(3-octylethiophene) (POT) and an ultrathin potassium-selective membrane. The experimental setup is designed to apply a potential in a three-electrode electrochemical cell with the ISE as the working electrode, while dynamic spectral changes in the POT film are simultaneously registered. The POT film is gradually oxidized to POT+, and this process is ultimately linked to K+ transfer at the membrane-sample interface, attending to electroneutrality requirements. The spectroelectrochemistry experiment provides two signals: a voltammetric peak and a transient absorbance response, with the latter of special interest because of its correspondence with the generated charge in the POT and thus with the ionic charge expelled from the membrane. By modifying how the ion analyte (K+ but also others) is initially accumulated into the membrane, we found three ranges of response for the absorbance: 10-950 nM for an accumulation-stripping protocol, 0.5-10 mu M in diffusion-controlled cyclic voltammetry, and 0.5-32 mM with thin-layer cyclic voltammetry. This wide response range is a unique feature, one that is rare to find for a sensor and indeed for any analytical technique. Accordingly, the developed sensor is highly appealing for many analytical applications, especially considering the versatility of samples and ion analytes that may be spotted.

Ämnesord

NATURVETENSKAP  -- Kemi -- Fysikalisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Physical Chemistry (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Liu, Yujie
Crespo, Gaston A ...
Cuartero, Maria, ...
Om ämnet
NATURVETENSKAP
NATURVETENSKAP
och Kemi
och Fysikalisk kemi
Artiklar i publikationen
Analytical Chemi ...
Av lärosätet
Kungliga Tekniska Högskolan

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy