SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Hertz E)
 

Sökning: WFRF:(Hertz E) > Can laboratory x-ra...

Can laboratory x-ray virtual histology provide intraoperative 3D tumor resection margin assessment?

Twengström, William (författare)
KTH,Kondenserade materiens teori,Biomedicinsk fysik och röntgenfysik,Exciscope AB, Torshamnsgatan 28A, S-16440 Kista, Sweden.
Moro, C. Fernandez (författare)
Karolinska Univ Hosp, Dept Clin Pathol & Canc Diagnost, SE-14186 Stockholm, Sweden.;Karolinska Univ Hosp Huddinge, Karolinska Inst, Dept Lab Med, Div Pathol F46, SE-14186 Stockholm, Sweden.
Romell, Jenny (författare)
KTH,Biomedicinsk fysik och röntgenfysik,Exciscope AB, Torshamnsgatan 28A, S-16440 Kista, Sweden.
visa fler...
Larsson, Jakob C. (författare)
KTH,Biomedicinsk fysik och röntgenfysik,Exciscope AB, Torshamnsgatan 28A, S-16440 Kista, Sweden.
Sparrelid, E. (författare)
Karolinska Inst, Dept Clin Sci Intervent & Technol, Div Surg, Stockholm, Sweden.
Bjornstedt, M. (författare)
Karolinska Univ Hosp, Dept Clin Pathol & Canc Diagnost, SE-14186 Stockholm, Sweden.;Karolinska Univ Hosp Huddinge, Karolinska Inst, Dept Lab Med, Div Pathol F46, SE-14186 Stockholm, Sweden.
Hertz, Hans (författare)
KTH,Biomedicinsk fysik och röntgenfysik
visa färre...
 (creator_code:org_t)
SPIE-Intl Soc Optical Eng, 2021
2021
Engelska.
Ingår i: DEVELOPMENTS IN X-RAY TOMOGRAPHY XIII. - : SPIE-Intl Soc Optical Eng.
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • Surgery is an essential part of the curative plan for most patients affected with solid tumors. The outcome of such surgery, e.g., recurrence rates and ultimately patient survival, depends on several factors where the resection margin is of key importance. Presently the resection margin is assessed by classical histology, which is time-consuming (several days), destructive, and basically only gives two-dimensional information. Clearly it would be advantageous if immediate feedback on tumor extension in all three dimensions were available to the surgeon intra-operatively. In the present paper we investigate a laboratory propagation-based phase-contrast x-ray computed tomography (CT) system that provides the resolution, contrast, and, potentially, the speed for this purpose. The system relies on a liquid-metal jet micro-focus source and a scintillator-coated CMOS detector. The study is performed on paraffin-embedded non-stained samples of human pancreatic neuroendocrine tumors, liver intrahepatic cholangiocarcinoma, and pancreatic serous cystic neoplasm (benign). We observe tumors with distinct and sharp edges having cellular resolution (similar to 10 mu m) as well as many assisting histological landmarks, allowing for resection margin assessment. All x-ray data is compared with classical histology. The agreement is excellent, and we conclude that the method has potential for intra-operative three-dimensional virtual histology.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
kon (ämneskategori)

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy