SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:1879 0534 OR L773:0010 4825
 

Sökning: L773:1879 0534 OR L773:0010 4825 > 3D numerical simula...

3D numerical simulation of hot airflow in the human nasal cavity and trachea

Shamohammadi, Hossein (författare)
Shiraz Univ, Sch Mech Engn, Shiraz, Iran.
Mehrabi, Samrad (författare)
Shiraz Univ Med Sci, Dept Internal Med, Shiraz, Iran.
Sadrizadeh, Sasan (författare)
KTH,Hållbara byggnader
visa fler...
Yaghoubi, Mahmood (författare)
Shiraz Univ, Sch Mech Engn, Shiraz, Iran.
Abouali, Omid (författare)
KTH,Byggvetenskap,Shiraz Univ, Sch Mech Engn, Shiraz, Iran
visa färre...
Shiraz Univ, Sch Mech Engn, Shiraz, Iran Shiraz Univ Med Sci, Dept Internal Med, Shiraz, Iran. (creator_code:org_t)
Elsevier BV, 2022
2022
Engelska.
Ingår i: Computers in Biology and Medicine. - : Elsevier BV. - 0010-4825 .- 1879-0534. ; 147, s. 105702-
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background and objective: The primary function of the human respiratory system is gas and moisture exchange, and conditioning inhaled air to prevent damage to the lungs and alveoli. In a fire incident, exposed soft tissues contract and the respiratory system may be severely damaged, possibly leading to respiratory failure and even respiratory arrest. The purpose of this study is to numerically simulate hot airflow in the human upper airway and trachea to investigate heat and moisture transfer and induced thermal injuries. Methods: For analysis, the airflow is assumed to be laminar and steady, and simulations have been carried out at volume flow rates of 5 and 10 L/min, inlet temperatures of 70-240 ?C, and relative humidity up to 40%. The mucous layer and surrounding tissues are incorporated into the conducting zone of the model. The blood perfusion is considered at different rates up to 5(Kg/m3.s) to regulate the temperature, and the vapor concentration is coupled with the energy equation. Results: The temperature and humidity distribution on the airway wall were calculated for all the studied conditions in order to find the mild and severe burn for different inhaled air temperatures. At the inlet temperatures of 70 and 100 ?C, there are mild burns in several nasal cavity regions. At the higher temperatures of 160 and 200 ?C, these areas suffer from severe burns and mild burns occur at the superior parts and nasopharynx. Rapid evaporation and tissue destruction will be observed if anyone breathes the 240 ?C air. Conclusions: The results show that the hot inlet temperatures drop below 44 ?C when passing through the upper airway, and the lower airway was not affected. Increasing the inlet temperature from 70 to 240 ?C extends the burns from mild to severe and the affected areas from the beginning of the nasal cavity to the pharynx.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Strömningsmekanik och akustik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Fluid Mechanics and Acoustics (hsv//eng)

Nyckelord

Computational fluid dynamics (CFD)
Human nasal cavity and trachea
Heat and moisture transfer
Blood perfusion rate
Thermal injury

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy