SwePub
Sök i LIBRIS databas

  Extended search

(LAR1:lu) lar1:(miun) mspu:(article) lar1:(kth)
 

Search: (LAR1:lu) lar1:(miun) mspu:(article) lar1:(kth) > Validation of a 3D ...

  • Jedenmalm, AnneliLunds universitet,KTH,Fiber- och polymerteknologi,Lund University, Sweden,KTH, Fiber- och polymerteknologi,Ortopedi, Lund,Sektion III,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Orthopaedics (Lund),Section III,Department of Clinical Sciences, Lund,Faculty of Medicine (author)

Validation of a 3D CT method for measurement of linear wear of acetabular cups : A hip simulator study

  • Article/chapterEnglish2011

Publisher, publication year, extent ...

  • 2011-02
  • Medical Journals Sweden AB,2011
  • printrdacarrier

Numbers

  • LIBRIS-ID:oai:DiVA.org:kth-31654
  • https://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-31654URI
  • https://doi.org/10.3109/17453674.2011.552777DOI
  • https://urn.kb.se/resolve?urn=urn:nbn:se:miun:diva-46896URI
  • https://lup.lub.lu.se/record/1832494URI
  • http://kipublications.ki.se/Default.aspx?queryparsed=id:122058160URI

Supplementary language notes

  • Language:English
  • Summary in:English

Part of subdatabase

Classification

  • Subject category:ref swepub-contenttype
  • Subject category:art swepub-publicationtype

Notes

  • QC 20110321
  • Material and methods Ultra-high molecular weight polyethylene cups with a titanium mesh molded on the outside were subjected to wear using a hip simulator. Before and after wear, they were (1) imaged with a CT scanner using a phantom model device, (2) measured using a coordinate measurement machine (CMM), and (3) weighed. CMM was used as the reference method for measurement of femoral head penetration into the cup and for comparison with CT, and gravimetric measurements were used as a reference for both CT and CMM. Femoral head penetration and wear vector angle were studied. The head diameters were also measured with both CMM and CT. The repeatability of the method proposed was evaluated with two repeated measurements using different positions of the phantom in the CT scanner. Results The accuracy of the 3D CT method for evaluation of linear wear was 0.51 mm and the repeatability was 0.39 mm. Repeatability for wear vector angle was 17 degrees A degrees. Interpretation This study of metal-meshed hip-simulated acetabular cups shows that CT has the capacity for reliable measurement of linear wear of acetabular cups at a clinically relevant level of accuracy.

Subject headings and genre

Added entries (persons, corporate bodies, meetings, titles ...)

  • Nilsson, FritjofKTH,Fiber- och polymerteknologi,KTH, Fiber- och polymerteknologi(Swepub:miun)frinil2200 (author)
  • Noz, Marilyn E.New York University, Department of Radiology (author)
  • Green, Douglas D.Loma Linda University, Orthopaedic Research Center (author)
  • Gedde, Ulf W.KTH,Fiber- och polymerteknologi,KTH, Fiber- och polymerteknologi(Swepub:kth)u1j56evm (author)
  • Clarke, Ian C.Loma Linda University, Orthopaedic Research Center (author)
  • Stark, AndreasKarolinska Institutet (author)
  • Maguire Jr., Gerald Q.KTH,Radio Systems Laboratory (RS Lab),Computer Communications,KTH, Radio Systems Laboratory (RS Lab)(Swepub:kth)u1d13i2c (author)
  • Zeleznik, Michael P.Saya Systems Inc., Salt Lake City, UT, USA (author)
  • Olivecrona, HenrikKarolinska Institute, Department of Molecular Medicine and Surgery (author)
  • KTHFiber- och polymerteknologi (creator_code:org_t)

Related titles

  • In:Acta Orthopaedica: Medical Journals Sweden AB82:1, s. 35-411745-36741745-3682

Internet link

Find in a library

To the university's database

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view