SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Edin K)
 

Sökning: WFRF:(Edin K) > Impact of Magnetic ...

Impact of Magnetic Field on Corona Discharge Behavior of Mineral Oil Under AC Voltage

Amizhtan, S. K. (författare)
Indian Inst Technol Madras, Dept Elect Engn, Chennai 600036, Tamil Nadu, India.
Amalanathan, A. J. (författare)
Indian Inst Technol Madras, Dept Elect Engn, Chennai 600036, Tamil Nadu, India.
Sarathi, R. (författare)
Indian Inst Technol Madras, Dept Elect Engn, Chennai 600036, Tamil Nadu, India.
visa fler...
Edin, Hans Ezz (författare)
KTH,Elektroteknisk teori och konstruktion
Taylor, Nathaniel, 1978- (författare)
KTH,Elektroteknisk teori och konstruktion
visa färre...
Indian Inst Technol Madras, Dept Elect Engn, Chennai 600036, Tamil Nadu, India Elektroteknisk teori och konstruktion (creator_code:org_t)
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC, 2022
2022
Engelska.
Ingår i: IEEE transactions on dielectrics and electrical insulation. - : IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. - 1070-9878 .- 1558-4135. ; 29:4, s. 1417-1424
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • This article reports an experimental investigation of the impact of magnetic field on corona discharge activity in mineral oil, using both ultrahigh-frequency (UHF) and fluorescence techniques under ac voltage. The results show that corona inception voltage (CIV) increased under ac voltage with varying harmonic frequencies without considering any phase shift and reduced marginally under magnetic field. In addition, the impact of the magnetic field shifted the dominating frequency of the UHF signal (0.9 GHz) obtained under ac voltage toward lower frequencies (0.3 and 0.6 GHz). Under high magnetic fields, the parameters such as rise time, fall time, and pulsewidth of the fluorescence signal increased in its magnitude compared to its effect without a magnetic field. Also, using both the UHF sensor and the fluorescence sensor, there was no clear difference in the phase-resolved partial discharge (PRPD) pattern caused by corona discharge (with and without magnetic field). Furthermore, the number of discharges is observed to be high under the impact of harmonic ac voltages with third- and seventh-order containing total harmonic distortions (THDs) of 4% and 40%.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik -- Annan elektroteknik och elektronik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering -- Other Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Produktionsteknik, arbetsvetenskap och ergonomi (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Production Engineering, Human Work Science and Ergonomics (hsv//eng)
NATURVETENSKAP  -- Fysik -- Atom- och molekylfysik och optik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Atom and Molecular Physics and Optics (hsv//eng)

Nyckelord

Oils
Magnetic fields
Partial discharges
Minerals
Discharges (electric)
Corona
Fluorescence
Discharges
drift motion
hysteresis
magnetic field
pulsewidth

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy