SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Capriata Corrado Carlo Maria)
 

Sökning: WFRF:(Capriata Corrado Carlo Maria) > Stochastic Magnetic...

Stochastic Magnetic Actuated Random Transducer Devices Based on Perpendicular Magnetic Tunnel Junctions

Rehm, L. (författare)
NYU, Ctr Quantum Phenomena, Dept Phys, New York, NY 10003 USA.
Capriata, Corrado Carlo Maria (författare)
KTH,Elektronik och inbyggda system,NYU, Ctr Quantum Phenomena, Dept Phys, New York, NY 10003 USA.
Misra, S. (författare)
Sandia Natl Labs, Albuquerque, NM 87185 USA.
visa fler...
Smith, J. D. (författare)
Sandia Natl Labs, Albuquerque, NM 87185 USA.
Pinarbasi, M. (författare)
Spin Memory Inc, Fremont, CA 94538 USA.
Malman, Bartosz (författare)
KTH,Elektronik och inbyggda system
Kent, A. D. (författare)
NYU, Ctr Quantum Phenomena, Dept Phys, New York, NY 10003 USA.
visa färre...
NYU, Ctr Quantum Phenomena, Dept Phys, New York, NY 10003 USA Elektronik och inbyggda system (creator_code:org_t)
American Physical Society (APS), 2023
2023
Engelska.
Ingår i: Physical Review Applied. - : American Physical Society (APS). - 2331-7019. ; 19:2
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • True random number generators are of great interest in many computing applications, such as cryptography, neuromorphic systems, and Monte Carlo simulations. Here, we investigate perpendicular magnetic-tunnel-junction nanopillars (pMTJs) activated by short-duration (nanosecond) pulses in the ballistic limit for such applications. In this limit, a pulse can transform the Boltzmann distribution of initial free-layer magnetization states into randomly magnetized down or up states, i.e., a bit that is 0 or 1, easily determined by measurement of the tunnel resistance of the junction. It is demonstrated that bit streams with millions of events: (1) are very well approximated by a normal distribution; (2) pass multiple statistical tests for true randomness, including all the National Institute of Standards and Technology tests for random number generators with only one XOR operation; (3) can be used to create a uniform distribution of 8-bit random numbers; and (4) can have no drift in the bit probability with time. The results presented here show that pMTJs operated in the ballistic regime can generate true random numbers at around 50-MHz bit rates, while being more robust to environmental changes, such as their operating temperature, compared to other stochastic nanomagnetic devices.

Ämnesord

NATURVETENSKAP  -- Fysik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy