SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Cuartero Maria PhD 1984 )
 

Sökning: WFRF:(Cuartero Maria PhD 1984 ) > Intradermal Glycine...

Intradermal Glycine Detection with a Wearable Microneedle Biosensor : The First In Vivo Assay

Wang, Qianyu (författare)
KTH,Tillämpad fysikalisk kemi,KTH Royal Inst Technol, Sch Engn Sci Chem, Dept Chem, Biotechnol & Hlth, S-10044 Stockholm, Sweden.
Molinero Fernandez, Agueda (författare)
KTH,Tillämpad fysikalisk kemi,KTH Royal Inst Technol, Sch Engn Sci Chem, Dept Chem, Biotechnol & Hlth, S-10044 Stockholm, Sweden.
Casanova, Ana (författare)
KTH,Tillämpad fysikalisk kemi,KTH Royal Inst Technol, Sch Engn Sci Chem, Dept Chem, Biotechnol & Hlth, S-10044 Stockholm, Sweden.
visa fler...
Titulaer, Joep (författare)
Section of Neuropharmacology and Addiction Research, Department of Pharmaceutical Biosciences, Uppsala University, SE-751 05 Uppsala, Sweden
Campillo-Brocal, Jonatan C. (författare)
Department of Genetics and Microbiology, University of Murcia, Campus Universitario de Espinardo, 30100 Murcia, Spain, Campus Universitario de Espinardo,Univ Murcia, Campus Univ Espinardo, Dept Genet & Microbiol, Murcia 30100, Spain.
Konradsson-Geuken, Åsa (författare)
Uppsala universitet,Institutionen för farmaceutisk biovetenskap,Sect Neuropharmacol & Addict Res
Crespo, Gaston A., 1980- (författare)
KTH,Tillämpad fysikalisk kemi,KTH Royal Inst Technol, Sch Engn Sci Chem, Dept Chem, Biotechnol & Hlth, S-10044 Stockholm, Sweden.
Cuartero, Maria, PhD, 1984- (författare)
KTH,Tillämpad fysikalisk kemi,KTH Royal Inst Technol, Sch Engn Sci Chem, Dept Chem, Biotechnol & Hlth, S-10044 Stockholm, Sweden.
visa färre...
 (creator_code:org_t)
2022-08-18
2022
Engelska.
Ingår i: Analytical Chemistry. - : American Chemical Society (ACS). - 0003-2700 .- 1520-6882. ; 94:34, s. 11856-11864
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Glycine (GLY) is gaining importance in medical diagnoses due to its relationship with multiple physiological functions. Today, GLY is exclusively analyzed using instrumentation centralized in clinical labs, and a tangible point-of-care tool that gathers real-time data from the patient for effective and fast evaluations is lacking. Relevant clinical advances are expected as soon as the rapid provision of both punctual and continuous measurements is possible. In that context, this work presents a microneedle (MN)-based biosensor for intradermal GLY detection in interstitial fluid (ISF). The MN tip is externally tailored to detect GLY levels through the hydrogen peroxide formed in its reaction with a quinoprotein-based GLY oxidase enzyme. The analytical performance of the MN biosensor indicates a fast response time (<7 s); acceptable reversibility, reproducibility, and stability; as well as a wide linear range of response (25-600 μM) that covers the physiological levels of GLY in ISF. The MN biosensor conveniently exhibits high selectivity for GLY over other compounds commonly found in ISF, and the response is not influenced by temperature, pH, or skin insertions. Validated intradermal measurements of GLY were obtained at the in vitro (with pieces of rat skin), ex vivo (on-body tests of euthanized rats) and in vivo (on-body tests of anesthetized rats) levels, demonstrating its ability to produce accurate physiological data. The developed GLY MN biosensor is skin-wearable and provides reliable, real-time intradermal GLY measurements in ISF by means of a minimally invasive approach.

Ämnesord

NATURVETENSKAP  -- Kemi -- Analytisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Analytical Chemistry (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy