SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Cuartero Maria PhD 1984 )
 

Sökning: WFRF:(Cuartero Maria PhD 1984 ) > Portable All-in-One...

Portable All-in-One Electrochemical Actuator-Sensor System for the Detection of Dissolved Inorganic Phosphorus in Seawater

Chen, Chen (författare)
KTH,Tillämpad fysikalisk kemi
Wiorek, Alexander (författare)
KTH,Tillämpad fysikalisk kemi
Gomis Berenguer, Alicia (författare)
visa fler...
Crespo, Gaston A., 1980- (författare)
KTH,Tillämpad fysikalisk kemi,UCAM-SENS, Universidad Católica San Antonio de Murcia, UCAM HiTech, Avda. Andres Hernandez Ros 1, 30107 Murcia, Spain, Avda. Andres Hernandez Ros 1
Cuartero, Maria, PhD, 1984- (författare)
KTH,Tillämpad fysikalisk kemi,UCAM-SENS, Universidad Católica San Antonio de Murcia, UCAM HiTech, Avda. Andres Hernandez Ros 1, 30107 Murcia, Spain, Avda. Andres Hernandez Ros 1
visa färre...
 (creator_code:org_t)
2023-02-01
2023
Engelska.
Ingår i: Analytical Chemistry. - : American Chemical Society (ACS). - 0003-2700 .- 1520-6882. ; 95:8, s. 4180-4189
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • We present a methodology for the detection of dissolved inorganic phosphorous (DIP) in seawater using an electrochemically driven actuator-sensor system. The motivation for this work stems from the lack of tangible solutions for the in situ monitoring of nutrients in water systems. It does not require the addition of any reagents to the sample and works under mild polarization conditions, with the sample confined to a thin-layer compartment. Subsequent steps include the oxidation of polyaniline to lower the pH, the delivery of molybdate via a molybdenum electrode, and the formation of an electroactive phosphomolybdate complex from DIP species. The phosphomolybdate complex is ultimately detected by either cyclic voltammetry (CV) or square wave voltammetry (SWV). The combined release of protons and molybdate consistently results in a sample pH < 2 as well as a sufficient excess of molybdate, fulfilling the conditions required for the stoichiometric detection of DIP. The current of the voltammetric peak was found to be linearly related to DIP concentrations between 1 and 20 μM for CV and 0.1 and 20 μM for SWV, while also being selective against common silicate interference. The analytical application of the system was demonstrated by the validated characterization of five seawater samples, revealing an acceptable degree of difference compared to chromatography measurements. This work paves the way for the future DIP digitalization in environmental waters by in situ electrochemical probes with unprecedented spatial and temporal resolution. It is expected to provide real-time data on anthropogenic nutrient discharges as well as the improved monitoring of seawater restoration actions.

Ämnesord

NATURVETENSKAP  -- Kemi -- Analytisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Analytical Chemistry (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy