SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:1473 0502 OR L773:1878 1683
 

Sökning: L773:1473 0502 OR L773:1878 1683 > (2020-2024) > Granulocyte concent...

Granulocyte concentrates prepared from residual leukocyte units produced by the Reveos automated blood processing system

Sahlin, Angelica (författare)
Linköpings universitet,Institutionen för biomedicinska och kliniska vetenskaper,Medicinska fakulteten,Region Östergötland, Klinisk immunologi och transfusionsmedicin
Blomgran, Robert (författare)
Linköpings universitet,Avdelningen för inflammation och infektion,Medicinska fakulteten
Berlin, Gösta (författare)
Linköpings universitet,Avdelningen för inflammation och infektion,Medicinska fakulteten,Region Östergötland, Klinisk immunologi och transfusionsmedicin
 (creator_code:org_t)
PERGAMON-ELSEVIER SCIENCE LTD, 2020
2020
Engelska.
Ingår i: Transfusion and apheresis science. - : PERGAMON-ELSEVIER SCIENCE LTD. - 1473-0502 .- 1878-1683. ; 59:2
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: Granulocyte concentrates are mainly derived by apheresis technique from donors stimulated with granulocyte colony-stimulating factor and steroids. The automated blood processing system Reveos, which is now increasingly used across the world, separates whole blood into four components, including a residual leukocyte unit containing granulocytes. The aim of this study was to produce an alternative granulocyte concentrate from leukocyte units produced by the Reveos system, and to assess the function of the granulocytes. Methods: The number of granulocytes was measured in residual leukocyte units, derived from whole blood donations, with different volumes ranging from 10 to 40 ml. After deciding the optimal volume of the leukocyte unit (30 ml), ten ABO-matched units were pooled to form a granulocyte concentrate. The function of the granulocytes from residual leukocyte units was assessed by analyzing surface markers, phagocytosis of yeast, and production of reactive oxygen species. Results: Residual leukocyte units with a volume of 30 ml contained a median number of 0,7 x 10(9) granulocytes, and granulocyte concentrates prepared from ten pooled 30 ml-leukocyte units contained a median number of 6,3 x 10(9) granulocytes. Granulocytes derived from residual leukocyte units displayed surface markers associated with granulocyte function, and capability to phagocytose yeast and produce reactive oxygen species. Conclusions: Granulocyte concentrates prepared from residual leukocyte units contain in vitro functional granulocytes and may be considered as an alternative product in acute situations before regular granulocyte concentrates from stimulated donors are available.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Hematologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Hematology (hsv//eng)

Nyckelord

Granulocyte concentrate; Granulocyte function; Reveos; Whole blood; Automated blood processing system

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Sahlin, Angelica
Blomgran, Robert
Berlin, Gösta
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Hematologi
Artiklar i publikationen
Transfusion and ...
Av lärosätet
Linköpings universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy