SwePub
Sök i LIBRIS databas

  Extended search

id:"swepub:oai:DiVA.org:kth-333776"
 

Search: id:"swepub:oai:DiVA.org:kth-333776" > Correlations betwee...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist
  • Dahlgren, GunillaUmeå universitet,Avdelningen för hållbar hälsa,Umeå Univ, Dept Publ Hlth & Clin Med, Sect Sustainable Hlth, S-90187 Umeå, Sweden. (author)

Correlations between Ratings and Technical Measurements in Hand-Intensive Work

  • Article/chapterEnglish2023

Publisher, publication year, extent ...

  • MDPI AG,2023
  • printrdacarrier

Numbers

  • LIBRIS-ID:oai:DiVA.org:kth-333776
  • https://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-333776URI
  • https://doi.org/10.3390/bioengineering10070867DOI
  • https://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-212749URI
  • http://kipublications.ki.se/Default.aspx?queryparsed=id:153331893URI

Supplementary language notes

  • Language:English
  • Summary in:English

Part of subdatabase

Classification

  • Subject category:ref swepub-contenttype
  • Subject category:art swepub-publicationtype

Notes

  • QC 20230810
  • An accurate rating of hand activity and force is essential in risk assessment and for the effective prevention of work-related musculoskeletal disorders. However, it is unclear whether the subjective ratings of workers and observers correlate to corresponding objective technical measures of exposure. Fifty-nine workers were video recorded while performing a hand-intensive work task at their workplace. Self-ratings of hand activity level (HAL) and force (Borg CR10) using the Hand Activity Threshold Limit Value(& REG;) were assessed. Four ergonomist observers, in two pairs, also rated the hand activity and force level for each worker from video recordings. Wrist angular velocity was measured using inertial movement units. Muscle activity in the forearm muscles flexor carpi radialis (FCR) and extensor carpi radialis (ECR) was measured with electromyography root mean square values (RMS) and normalized to maximal voluntary electrical activation (MVE). Kendall's tau-b correlations were statistically significant between self-rated hand activity and wrist angular velocity at the 10th, 50th, and 90th percentiles (0.26, 0.31, and 0.23) and for the ratings of observers (0.32, 0.41, and 0.34). Significant correlations for force measures were found only for observer-ratings in five of eight measures (FCR 50th percentile 0.29, time > 10%MVE 0.43, time > 30%MVE 0.44, time < 5% -0.47) and ECR (time > 30%MVE 0.26). The higher magnitude of correlation for observer-ratings suggests that they may be preferred to the self-ratings of workers. When possible, objective technical measures of wrist angular velocity and muscle activity should be preferred to subjective ratings when assessing risks of work-related musculoskeletal disorders.

Subject headings and genre

Added entries (persons, corporate bodies, meetings, titles ...)

  • Liv, Per,1979-Umeå universitet,Avdelningen för hållbar hälsa,Umeå Univ, Dept Publ Hlth & Clin Med, Sect Sustainable Hlth, S-90187 Umeå, Sweden.(Swepub:umu)perliv00 (author)
  • Öhberg, Fredrik,1969-Umeå universitet,Radiofysik,Umeå Univ, Dept Radiat Sci, Radiat Phys, S-90187 Umeå, Sweden.(Swepub:umu)froh0003 (author)
  • Slunga-Järvholm, LisbethUmeå universitet,Avdelningen för hållbar hälsa,Umeå Univ, Dept Publ Hlth & Clin Med, Sect Sustainable Hlth, S-90187 Umeå, Sweden.(Swepub:umu)lisl0003 (author)
  • Forsman, Mikael,ProfessorKarolinska Institutet,KTH,Ergonomi,Karolinska Inst, IMM Inst Environm Med, S-17177 Stockholm, Sweden.,IMM Institute of Environmental Medicine, Karolinska Institutet, Stockholm, Sweden; Division of Ergonomics, School of Engineering Sciences in Chemistry, Biotechnology and Health, KTH Royal Institute of Technology, Hälsovägen 11C, Huddinge, Sweden(Swepub:kth)u1iq0ct2 (author)
  • Rehn, Börje,1967-Umeå universitet,Avdelningen för fysioterapi,Umeå Univ, Dept Community Med & Rehabil, Physiotherapy, S-90187 Umeå, Sweden.(Swepub:umu)bore0002 (author)
  • Umeå universitetAvdelningen för hållbar hälsa (creator_code:org_t)

Related titles

  • In:Bioengineering: MDPI AG10:72306-5354

Internet link

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view