SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Norrga Staffan 1968 )
 

Sökning: WFRF:(Norrga Staffan 1968 ) > Design of backup pr...

Design of backup protection for the DC interconnection of adjacent point-to-point HVDC systems

Chaffey, Geraint (författare)
Dept. Electrical Engineering, KU Leuven/EnergyVille, Leuven, Belgium
Jahn, Ilka (författare)
KTH,Elkraftteknik
Nahalparvari, Mehrdad (författare)
KTH,Elkraftteknik
visa fler...
Wang, Mian (författare)
Dept. Electrical Engineering, KU Leuven/EnergyVille, Leuven, Belgium
Van Hertem, Dirk (författare)
Dept. Electrical Engineering, KU Leuven/EnergyVille, Leuven, Belgium
Norrga, Staffan, 1968- (författare)
KTH,Elkraftteknik
visa färre...
Dept Electrical Engineering, KU Leuven/EnergyVille, Leuven, Belgium Elkraftteknik (creator_code:org_t)
Institution of Engineering and Technology (IET), 2022
2022
Engelska.
Ingår i: Proceedings 16th International Conference on Developments in Power System Protection, DPSP 2022. - : Institution of Engineering and Technology (IET). ; , s. 25-30
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)
Abstract Ämnesord
Stäng  
  • In order to provide additional flexibility in future power systems, it could be beneficial to connect existing point-to-point highvoltage direct-current (HVDC) systems at the DC-side into a multiterminal network. Such a network would allow increased operational flexibility, continued operation in case of maintenance, and could reduce the end-to-end losses in the overall system. The protection of such a system, however, poses interesting challenges with constraints which differ slightly from typical HVDC grid protection studies. This paper focuses on the trade-offs surrounding the backup protection strategy following failure of a DC circuit breaker in the primary protection role. For this particular application, where a control retrofit should be avoided, the focus is on enabling quicker recovery rather than attempting to maintain continuous operation on a charged and healthy network. Therefore, the functional requirements on the backup switchgear are in some respects reduced compared to that required for primary protection. The benefits of reduced voltage switchgear for this backup protection application are therefore investigated.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik -- Annan elektroteknik och elektronik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering -- Other Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)

Nyckelord

HVDC CIRCUIT BREAKER
HVDC PROTECTION
MULTITERMINAL DC GRIDS
MULTIVENDOR HVDC
PROTECTION SYSTEM DESIGN

Publikations- och innehållstyp

vet (ämneskategori)
kon (ämneskategori)

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Chaffey, Geraint
Jahn, Ilka
Nahalparvari, Me ...
Wang, Mian
Van Hertem, Dirk
Norrga, Staffan, ...
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Elektroteknik oc ...
och Annan elektrotek ...
Artiklar i publikationen
Av lärosätet
Kungliga Tekniska Högskolan

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy