  • Fredenberg, Erik,PhD,1979-KTH,Medicinsk bildfysik (författare)

Contrast-enhanced dual-energy subtraction imaging using electronic spectrum-splitting and multi-prism x-ray lenses

  • Artikel/kapitelEngelska2008

Förlag, utgivningsår, omfång ...

  • San Diego, CA, USA :SPIE,2008
  • electronicrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:kth-38400
  • https://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-38400URI
  • https://doi.org/10.1117/12.770501DOI
  • https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-110856URI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:kon swepub-publicationtype

Serie

  • Proceedings of the Society of Photo-Optical Instrumentation Engineers,0277-786X ;6913

Anmärkningar

  • QC 20210121
  • Dual-energy subtraction imaging (DES) is a method to improve the detectability of contrast agents over a lumpy background. Two images, acquired at x-ray energies above and below an absorption edge of the agent material, are logarithmically subtracted, resulting in suppression of the signal from the tissue background and a relative enhancement of the signal from the agent. Although promising, DES is still not widely used in clinical practice. One reason may be the need for two distinctly separated x-ray spectra that are still close to the absorption edge, realized through dual exposures which may introduce motion unsharpness. In this study, electronic spectrum-splitting with a silicon-strip detector is theoretically and experimentally investigated for a mammography model with iodinated contrast agent. Comparisons are made to absorption imaging and a near-ideal detector using a signal-to-noise ratio that includes both statistical and structural noise. Similar to previous studies, heavy absorption filtration was needed to narrow the spectra at the expense of a large reduction in x-ray flux. Therefore, potential improvements using a chromatic multi-prism x-ray lens (MPL) for filtering were evaluated theoretically. The MPL offers a narrow tunable spectrum, and we show that the image quality can be improved compared to conventional filtering methods.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Cederström, BjörnKTH,Medicinsk bildfysik(Swepub:kth)u1oerth9 (författare)
  • Lundqvist, Mats (författare)
  • Ribbing, CarolinaUppsala universitet,Fasta tillståndets elektronik(Swepub:uu)cri24390 (författare)
  • Åslund, Magnus (författare)
  • Diekmann, FelixCharité - Univ. Hospital (Germany) (författare)
  • Nishikawa, RobertUniv. of Chicago (United States) (författare)
  • Danielsson, MatsKTH,Medicinsk bildfysik(Swepub:kth)u1m3qe0f (författare)
  • KTHMedicinsk bildfysik (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Medical Imaging 2008 - Physics of Medical ImagingSan Diego, CA, USA : SPIE, s. 91310-913109780819470973

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy