SwePub
Sök i LIBRIS databas

  Extended search

WFRF:(Koelling Sebastian)
 

Search: WFRF:(Koelling Sebastian) > Characteristics of ...

Characteristics of cross-sectional atom probe analysis on semiconductor structures

Koelling, Sebastian (author)
Imec, Kapeldreef 75, B-3000 Leuven, Belgium
Innocenti, Nicolas, 1986- (author)
Imec, Kapeldreef 75, B-3000 Leuven, Belgium; University of Liege, Institut Montefiore
Hellings, Geert Hellings (author)
Imec, Kapeldreef 75, B-3000 Leuven, Belgium
show more...
Gilbert, Matthieu (author)
Imec, Kapeldreef 75, B-3000 Leuven, Belgium
Kambham, Ajay Kumar (author)
Imec, Kapeldreef 75, B-3000 Leuven, Belgium
De Meyer, Kristin (author)
Imec, Kapeldreef 75, B-3000 Leuven, Belgium
Vandervorst, Wilfried (author)
Imec, Kapeldreef 75, B-3000 Leuven, Belgium
show less...
 (creator_code:org_t)
Elsevier BV, 2011
2011
English.
In: Ultramicroscopy. - : Elsevier BV. - 0304-3991 .- 1879-2723. ; 111:6, s. 540-545
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • The laser-assisted Atom Probe has been proposed as a metrology tool for next generation semiconductor technologies requiring sub-nm spatial resolution. In order to assess its potential for the analysis of three-dimensional semiconductor structures like FinFETs, we have studied the Atom Probes lateral resolution on a silicon, silicon–germanium multilayer structure. We find that the interactions of the laser with the semiconductor materials in the sample distort the sample surface. This results in transient errors of the measured dimensions of the structure. The deformation of the sample furthermore leads to a degradation of the lateral resolution. In the experiments presented in this paper, the Atom Probe reaches a lateral resolution of 1-1.8 nm/decade. In this paper we will discuss the reasons for the distortions of the tip and demonstrate that with the present state of data reconstruction severe quantification errors limit its applicability for the quantitative analysis of heterogeneous semiconductor structures. Our experiments show that reconstruction algorithms taking into account the time dependent nanostructure of the tip shape are required to arrive at accurate results.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Nanoteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Nano-technology (hsv//eng)

Keyword

Laser-assisted Atom Probe
Cross-section analysis
SIMS
SRA - ICT
SRA - Informations- och kommunikationsteknik

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view