Enhancing the utility of ProstaScint SPECT scans for patient management

Noz, Marilyn E. (författare)
New York University, Department of Radiology,Nuclear Medicine
Chung, Grace (författare)
New York University
Lee, Benjamin Y. (författare)
New York University
visa fler...
Maguire Jr., Gerald Q. (författare)
KTH,Kommunikationssystem, CoS,Computer Communications
DeWyngaert, J. Keith (författare)
New York University
Doshi, Jay V. (författare)
New York University, Department of Radiology
Kramer, Elissa L. (författare)
New York University, Department of Radiology
Murphy-Walcott, Antoinette D. (författare)
New York University
Zeleznik, Michael P. (författare)
Saya Systems Inc., Salt Lake City, UT, USA
Kwak, Noeun G. (författare)
UMDNJ --- Robert Wood Johnson Medical School, Piscataway, NJ, USA
visa färre...
 (creator_code:org_t)
Springer-Verlag New York, 2006
2006
Engelska.
Ingår i: Journal of medical systems. - : Springer-Verlag New York. - 0148-5598 .- 1573-689X. ; 30:2, s. 123-132
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • This project investigated reducing the artifact content of In-111 ProstaScint SPECT scans for use in treatment planning and management. Forty-one patients who had undergone CT or MRI scans and simultaneous Tc-99m RBC/In-111 ProstaScint SPECT scans were included. SPECT volume sets, reconstructed using Ordered Set-Expectation Maximum (OS-EM) were compared against those reconstructed with standard Filtered Back projection (FBP). Bladder activity in Tc-99m scans was suppressed within an ellipsoidal volume. Tc-99m voxel values were subtracted from the corresponding In-111 after scaling based on peak activity within the descending aorta. The SPECT volume data sets were merged with the CT or MRI scans before and after processing. Volume merging, based both on visual assessment and statistical evaluation, was not affected. Thus iterative reconstruction together with bladder suppression and blood pool subtraction may improve the interpretation and utility of ProstaScint SPECT scans for patient management.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

Aged Aged
80 and over Humans Male Middle Aged Patient Care Prostatic Neoplasms Retrospective Studies Tomography
Emission-Computed
Single-Photon
SRA - ICT
SRA - Informations- och kommunikationsteknik

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy