SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Kramer Elissa L.)
 

Sökning: WFRF:(Kramer Elissa L.) > (1990-1994) > Hepatic hemangiomas...

Hepatic hemangiomas: diagnosis with fusion of MR, CT, and Tc-99m-labeled red blood cell SPECT images

Birnbaum, Bernard A. (författare)
New York University
Noz, Marilyn E. (författare)
New York University
Chapnick, Jeffrey V. (författare)
New York University
visa fler...
Sanger, Joseph J. (författare)
New York University
Megibow, Alec J. (författare)
New York University
Maguire Jr., Gerald Q. (författare)
Columbia University, Department of Computer Science
Weinreb, Jeffrey C. (författare)
New York University
Kaminer, Evan M. (författare)
New York University
Kramer, Elissa L. (författare)
New York University
visa färre...
 (creator_code:org_t)
Radiological Society of North America, 1991
1991
Engelska.
Ingår i: Radiology. - : Radiological Society of North America. - 0033-8419 .- 1527-1315. ; 181:2, s. 469-474
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • A method of image analysis was developed for correlation of hemangiomas detected at computed tomography {(CT)} and/or magnetic resonance {(MR)} imaging with increased blood pool activity evident at single photon emission {CT} {(SPECT)} performed after labeling of red blood cells with technetium-99m. Image analysis was performed in 20 patients with 35 known hepatic hemangiomas. After section thickness and pixel sizes of the different studies were matched, intrinsic landmarks were chosen to identify anatomically corresponding locations. Regions of interest {(ROIs)} drawn on the {CT} and/or {MR} images were translated, rotated, and reprojected to match the areas of interest on the corresponding {SPECT} images by means of a two-dimensional polynomial-based warping algorithm. Analysis of {ROIs} on 30 {SPECT-MR} and 20 {SPECT-CT} pairs of registered images provided absolute confirmation that 34 suspected hemangiomas identified on {SPECT} images correlated exactly with lesions seen on {CT} and/or {MR} images. Accuracy of fusion was within an average of 1.5 pixels +/- 0.8 (+/- 1 standard deviation). The technique enabled diagnostic confirmation of hemangiomas as small as 1.0 cm and proved useful for evaluating lesions located adjacent to intrahepatic vessels.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

Adult
Aged
Erythrocytes
Female
Hemangioma
Humans
Image Processing
{Computer-Assisted}
Liver
Liver Neoplasms
Magnetic Resonance Imaging
Male
Middle Aged
Tomography
{Emission-Computed}
{Single-Photon}
Tomography
{X-Ray} Computed
SRA - ICT
SRA - Informations- och kommunikationsteknik

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

  • Radiology (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy